Enviro EG40 BV NG Скачать руководство пользователя страница 2

2

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, 

PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

•  All ENVIRO gas-fired appliances must be installed 

in accordance with their instructions. Carefully read all 

the instructions in this manual first. Consult the building 

authority having jurisdiction to determine the need for 

a permit prior to commencing the installation.
•   

NOTE:

  Failure  to  follow  these  instructions  could 

cause  a  malfunction  of  the  fireplace,  which  could 

result in death, serious bodily injury, and/or property 

damage.
•  Failure to follow these instructions may also void 

your fire insurance and/or warranty.

GENERAL

•  Installation  and  repair  should  be  done  by  a 

qualified  service  person.  The  appliance  should  be 

inspected before the first use and, at least, annually 

by  a  qualified  service  person.  More  frequent 

cleaning  may  be  required  due  to  excessive  lint  from 

carpeting, bedding material, etc.  It is imperative the 

control  compartments,  burners  and  circulating  air 

passageways of the appliance be kept clean.
•  Due  to  high  temperatures,  the  appliance  should 

be  located  out  of  high  traffic  areas  and  away  from 

furniture and draperies.

Children  and  adults  should  be  alerted  to  the 

hazards  of  high  surface  temperatures  and 

should  stay  away  to  avoid  burn  or  clothing 

ignition.

•  Young  children  should  be  carefully  supervised 

when in the same room as the appliance.
•  Clothing or other flammable materials should not 

be placed on or near the appliance.

FOR YOUR SAFETY

•  Installation and service must be performed by a 

qualified installer, service agency or gas supplier.
•  This installation must conform to local codes or, in 

the absence of local codes, to the current CAN/CGA-

B149 installation code (Canada) or National Fuel Gas 

Code ANSI Z223.1.2 (USA)

•  To  prevent  injury,  do  not  allow  anyone  who  is 

unfamiliar with the stove to operate it.

 

To  prevent  injury,  if  the  pilot  or  pilot  and 

burners have gone out on their own, open the 

glass door and wait 5 minutes to air out before 

attempting to re-light the stove.

•  Always  keep  the  area  around  these  appliances 

clear  of  combustible  material,  gasoline  and  other 

flammable liquids and vapours.
•  These appliances should not be used as a drying 

rack for clothing or for hanging Christmas stockings/

decorations.
•  Due to the paint curing on the stove, a faint odor 

and  slight  smoking  will  likely  be  noticed  when  the 

stove is first used.  Open a window until the smoking 

stops.
Always connect this gas stove to a vent system and 

vent  to  the  outside  of  the  building  envelope.  Never 

vent to another room or inside the building. Make sure 

the specified vent pipe is used, properly sized and of 

adequate  height  to  provide  sufficient  draft.    Inspect 

the venting system annually for blockage and signs of 

deterioration.

WARNING: 

Failure to position the parts in accordance 

with the diagrams in this booklet, or failure to use only 

parts  specifically  approved  with  this  appliance,  may 

result in property damage or personal injury.

WARNING: 

Do  not  operate  with  the  glass  front 

removed,  cracked  or  broken.    Replacement  of  the 

glass should be done by a licensed or qualified service 

person.
•  Never  use  solid  fuels  such  as  wood,  paper, 

cardboard, coal, or any flammable liquids, etc., in this 

appliance.
•  Do not use this heater if any part has been under 

water. Immediately call a qualified service technician 

to inspect the heater and to replace any part of the 

control or gas control systems that have been under 

water.
•  Do not abuse the glass by striking it or slamming 

the door shut.

Safety Precautions

Содержание EG40 BV NG

Страница 1: ...instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage per...

Страница 2: ...to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury...

Страница 3: ...oval 9 Replacing The Blower 9 Fuel Conversion 10 Initial Installation 12 Preparation For Installation 12 Clearances to Combustibles 12 Flue Gas Spill Switch 12 Venting 13 Manufacturer s General Ventin...

Страница 4: ...UDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO EG40 BV Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use...

Страница 5: ...mensions 25 635 mm 21 533 mm 12 1 2 318 mm 4 5 8 117 mm 29 1 8 740 mm Shipping Weight 256 lbs 116 kg Figure 1 EG40 Exterior Dimensions Rating Label Location The rating label is found inside the right...

Страница 6: ...attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace...

Страница 7: ...e of medium height If the flames look like this no venturi adjustment is needed If the flames are fairly short and mostly blue the fireplace is getting too much air Therefore the venturies should be c...

Страница 8: ...roblem Depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available...

Страница 9: ...rs and the door has been resealed re light the pilot following the instructions on the lighting label attached to the unit Cleaning Plated Surfaces It is important to note that fingerprints and other...

Страница 10: ...re explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The...

Страница 11: ...re 11 O ring on valve screw is similar to what is shown in Figure 6 On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly installe...

Страница 12: ...circulation and comfort As the stove is equipped with a convection fan ensure that an electrical outlet is within 6 ft 1 8 m of the stove The flow of combustion and ventilation air must not be obstru...

Страница 13: ...ING A SEPARATE SOLID FUEL BURNING APPLIANCE Manufacturer s General Venting Guidelines This information is compiled by the manufacturer as a very general rule for single appliance venting of the EG40 g...

Страница 14: ...This basic venting configuration shown are rough guidelines only Follow national and local codes for other installation options Measure the height of the chimney beforehand and purchase the appropriat...

Страница 15: ...tal run The venting should never slope down a minimum inch 0 6 cm rise is needed for every 2 ft 61 cm of horizontal is recommended If practical it is best to locate the appliance to permit the use of...

Страница 16: ...ing instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and must be plugged directly into a properly grounded three prong outlet DO NOT c...

Страница 17: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water soluti...

Страница 18: ...ly See Figure 20 or 23 for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose Carefully remove logs from box Check to ensure there is no...

Страница 19: ...ight up watch for ignition to ALL burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to carefully reposition the embers making s...

Страница 20: ...low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line...

Страница 21: ...ow 18 Long EC 024 6 Burner Switch EC 025 7 Miniature Light Bulb 115V EC 031 7 Light Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Body Wiring Harness EC 037A Burner Wiring Harness EC 037B...

Страница 22: ...302 22 Fan Mount EG40 304 23 Pedestal Box Cover EG40 307 24 Burner Control Assembly NG 30 014 24 Burner Control Assembly LP 30 015 25 Front Pan Burner 30 016 26 Rear Burner with Venturi 30 017 Pilot 1...

Страница 23: ...23 Parts Diagram Chassis 16 1 29 22 2 15 23 19 20 13 18 8 14 EG 40 Body Chassis July 2004...

Страница 24: ...Parts Diagram Gas Tray Door EG40 Gas Tray Door Assemblies July 2004 28 9 21 10 24 3 5 6 11 7 12 17 27 26 25 4 24...

Страница 25: ...ctly or indirectly caused by improper usage operation installation servicing or maintenance of this appliance A proof of original purchase must be provided by you or the dealer Exclusions An expanded...

Страница 26: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Отзывы: