background image

 

 

2

SAFETY PRECAUTIONS 

FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIRO" STOVE, PLEASE, 

CAREFULLY READ THE FOLLOWING INFORMATION: 

 

GENERAL 

• 

Installation and repair should be done by a 

qualified service person. The appliance should 
be inspected before use and at least once per 
year by a qualified service person. More 
frequent cleaning may be required due to 
excessive lint from carpeting, bedding material, 
etc.  It is imperative that control compartments, 
burners and circulating air passageways of the 
appliance be kept clean. 
 

• 

Due to high temperatures the appliance 

should be located out of high traffic areas and 
away from furniture and draperies. 
Children and adults should be alerted to 
hazards of high surface temperatures and 
should stay away to avoid burns or clothing 
ignition. 
 

• 

Young children should be carefully 

supervised when they are in the same room as 
the appliance.   
 

• 

Clothing or other flammable material should 

not be placed on or near the appliance.   

 

• 

All "ENVIRO" gas-fired appliances must be 

installed in accordance with these instructions.  
Carefully read all the instructions in this manual first.  
Consult the building authority having jurisdiction to 
determine the need for a permit prior to commencing 
the installation. 
 

• 

NOTE 

Failure to follow these instructions could 

cause a malfunction of the fireplace, which could 
result in death, serious bodily injury, and/or property 
damage.   
 

• 

Failure to follow these instructions may also void 

your fire insurance and/or warranty. 
 

FOR YOUR SAFETY:

 

• 

Installation and service. Must be performed by a 

qualified installer, service agent, or gas supplier. 

• 

Installation must conform to local codes or, in 

the absence of local codes with the current CAN1-B 
149 installation code in Canada or the current 
National Fuel Gas Code ANSI Z223.1 in the USA. 
 

• 

To prevent injuries do not allow anyone who is 
unfamiliar with the operation to use the stove.   

 

• 

Always keep the appliance area clear 

and free of combustible materials, gasoline 
and other flammable vapors and

 

liquids.

   

 

• 

These appliances should not be used as a 

drying rack for clothing or for hanging Christmas 
stockings or decorations. 
 

• 

Due to the paint curing on the stove a faint odor 

and slight smoking will likely be noticed when the 
stove is first used.  Open a window until the slight 
smoking stops. Always connect this gas stove to a 
chimney and vent to the outside of the building 
envelope.  Never vent to another room or inside a 
building. Make sure you use the vent pipe that is 
specified. Make sure that the vent is properly sized 
and is of adequate height to provide the proper draft.  
Inspect the venting system annually for blockage 
and any signs of deterioration. 

 

WARNING:

 Do not operate with 

cracked or broken glass.  Under no 
circumstances should this appliance be 
modified.  Parts that have to be removed 
for servicing must be replaced prior to 
operating this appliance. Only parts 
supplied by Enviro should be used in 
this appliance and replacement should 
only be performed by a licensed or 
qualified service person.  

 

• 

Never use solid fuels such as wood, paper, 

cardboard, coal, or any other flammable liquids etc., 
in this appliance. 
 

• 

Do not use this heater if any part has been 

under water.  Immediately call a qualified service 
technician to inspect the heater and to replace any 
part of the control system and any gas control, which 
has been under water. 
 

• 

Do not abuse glass

 

by striking or slamming door 

shut. 

Содержание EG-40

Страница 1: ...on may result causing property damage personal injury or loss of life installation and service must be performed by a qualified installer service agency or the gas supplier Do not store or use gasolin...

Страница 2: ...tallation must conform to local codes or in the absence of local codes with the current CAN1 B 149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA To prevent i...

Страница 3: ...IGH ALTITUDE SPECS ENVIRO EG 40 DIRECT VENT UNITS Have all been certified for use with either natural or propane gases See control panel and rating label Are not for use with solid fuels Must not be c...

Страница 4: ...aintenance Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building E g cutting a wall or ceiling joist The stove can be installed...

Страница 5: ...inimum K Clearance to a mechanical air supply inlet 6 feet 1 8m minimum L Clearance above paved side walk or paved driveway located on public property 7 feet 2 1m minimum M Clearance under verandah po...

Страница 6: ...PERMITTED TO REACH THE OUTSIDE VENT TERMINATION BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMINATION CAN BE ACCOMMODATED FOLLOW THE VENT LENG...

Страница 7: ...dentations located on the female end of the pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe indentations so they match an...

Страница 8: ...nts excessive heat from possibly melting the vinyl siding material Note that the horizontal vent termination bolts onto the flat portion of the vinyl siding standoff Shaded area in FIG 12 so that an a...

Страница 9: ...pipe and elbows may be utilized in the attic as well as above the roofline The galvanized finish is desirable above the roofline due to the higher corrosion resistance STEP 6 Once the pipe sections h...

Страница 10: ...t the second floor and any subsequent floors FIG 19 The opening should be framed to 10 inch x 10 inch inside dimensions in the same manner as shown in FIG 16 2 Any occupied areas above the first floor...

Страница 11: ...ide on a location for the unit that will meet any or all local code requirements Refer to sections in this manual Deciding Were To Locate Your Stove and Planning Your Installation Set the appliance in...

Страница 12: ...liner over collar secure the flex liner with 3 sheet metal screws evenly spaced Align all straight sections of pipe slipping all joints together and installing 3 sheet metal screws evenly spaced A sm...

Страница 13: ...nimum 4 flex liner to the top of the CLASS A chimney Placing a bead of high temperature silicone to the Simpson Cap adapter and securely attach the flex liner to the adapter Secure the cap adapter to...

Страница 14: ...t is very important to install these logs in their correct position to insure safe optimum operating conditions Open the door of the fireplace Place the logs on the log supports Close the door and tig...

Страница 15: ...f all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the fl...

Страница 16: ...first 4 hours of use See page 14 After that depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a so...

Страница 17: ...d Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile if low see Pilot will...

Страница 18: ...the current edition of the National Fuel Gas Code ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON WARNOCK HERSEY RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pres...

Страница 19: ...ly to the floor WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a properly gr...

Страница 20: ...Voltage Thermostat REMOVING THE BLOWER 20 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burne...

Страница 21: ...lot orifice First remove the two 2 T 20 Torx screws that hold the pilot assembly to the burner tray Lift the pilot assembly from the burner tray Using a 10mm wrench disconnect the pilot line from the...

Страница 22: ...ts only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under t...

Страница 23: ...g Harness Complete 2 pieces 30 014 Freestanding Burner Control NG Complete EC 040 Freestanding Fan Control Knob 30 015 Freestanding Burner Control LP Complete EC 043 IEC Power Cord 30 017 Rear Burner...

Страница 24: ...r 2003 EG40 GAS TRAY AND DOOR ASSEMBLIES Rear Venturi EG40 099 S I T Nova 820 Valve EC 006 NG EC 007 LPG S I T Piezo Ignitor EC 023 Burner Switch EC 025 Light Switch EC 066 FS Fan Controller EF 045 FS...

Страница 25: ...ing Side Panel Cabinet EG40 086 Flue Pipe Freestanding Pedestal Wiring Plate Freestanding Pedestal Box Cover EG40 307 1x1 Side Cabinet Hinge EC 054 Freestanding Side Panel Cabinet EG40 086 Convection...

Страница 26: ..._________ Name of Installer ___________________________________________ Address _______________________________________ ___________________________________________ ____________________________________...

Отзывы: