background image

 

TABLE OF CONTENTS 

 
Safety Precautions 

Code Approvals 

Deciding where to locate your stove 

4-5 

Venting 

Installation of Log Sets and Embers 

Operating Instructions 

Maintenance and Technical 

10 

Trouble Shooting 

11 

Gas Line Connection 

12 

Electrical  

13 

Parts and Accessories  

14 

Fuel Type Conversion 

15 

Warranty 

16 

Parts List 

17 

Exploded Views 

18-19 

Installation Data Sheet 

20 

 
 

CODE APPROVALS 

 

• 

This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L 

vent.  May also be vented through a conventional chimney using a chimney liner kit. 
 
This appliance have been tested by INTERTEK TESTING SERVICES (WH) and found to comply with the 
established standards for a VENTED GAS FIREPLACE HEATER in CANADA and the USA as follows:- 

 

LISTED GAS FIRED VENTED ROOM HEATER (EG 28 BV. Nat. & LPG.) 

TESTED TO: ANSI Z21.88-1998      CSA 2.33-M98 VENTED GAS FIREPLACE HEATER 
CGA 2.17-M91 GAS FIRED APPLIANCES FOR USE AT HIGH ALTITUDE 

 

SPECS: 

ENVIRO EG 28 B VENT UNITS;

 

• 

Have all been certified for use with either natural or propane gases. (See control panel and rating label.) 

• 

Are not for use with solid fuels. 

• 

Must not be connected to a chimney flue serving a separate solid-fuel burning appliance. 

• 

Are approved for bedroom or bedsitting room.   

 

(

IN CANADA

: must be installed with a listed wall thermostat) 

(

IN USA

: see current ANSI Z223.1 for installation instructions.) 

• 

Must be installed in accordance with local codes if any.  If none exist, use current installation code CAN/CGA 
- B149 in Canada or ANSI Z223.1 / NFPA 54 in the USA. 

• 

Must be properly connected to an approved venting system. 

• 

Are approved for installation on combustible materials.  

• 

Are not approved for closet or recessed installations. 

 

FOR INSTALLATIONS: ABOVE 2000 FEET (610 m). 

In Canada these appliances must have the input de-rated by 10% as per the gas code. 
In the USA these appliances must have the inputs de-rated by 4% for every 1000 feet (305m) above sea level. 
 

 

ASSEMBLY INSTRUCTIONS 

Remove the packaging from the appliance, check to make sure there is no damage.  If damage is found, PREPARATION FOR 
INSTALLATION 

• 

Please report it to both the carrier and your dealer as soon as possible. 

• 

Before beginning, carefully check the glass door and the log set

 

 

 

3

Содержание EG 28 B

Страница 1: ...esult causing property damage personal injury or loss of life installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use...

Страница 2: ...tion must conform to local codes or in the absence of local codes with the current CAN CGA B149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA To prevent inju...

Страница 3: ...d for use with either natural or propane gases See control panel and rating label Are not for use with solid fuels Must not be connected to a chimney flue serving a separate solid fuel burning applian...

Страница 4: ...the flue system of the stove can be properly installed without damaging the integrity of the building e g cutting a wall or ceiling joist The stove can be installed on any standard flooring materials...

Страница 5: ...within 3 feet 90cm horizontally from the center line of the regulator I Clearance to service regulator vent outlet 6 feet 1 8m minimum J Clearance to non mechanical air supply inlet to building or the...

Страница 6: ...CING A SEPARATE SOLID FUEL BURNING APPLIANCE FLUE GAS SPILL SWITCH NOTE THIS HEATER MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM THIS HEATER IS EQUIPPED WITH A VENT SAFETY SHUTOFF SYSTEM DESIGNED TO...

Страница 7: ...te provincial codes regarding the suitability of your application For other special venting requirements please refer to the local state provincial or national codes For best venting performance we re...

Страница 8: ...ition to insure safe optimum operating conditions 1 Open the front door 2 Place each piece of the log set into the firebox resting the pins in the holes in the logs 3 Close the door and tighten secure...

Страница 9: ...f all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the fl...

Страница 10: ...will expose a door fastener Using a 1 2 wrench loosen the fastener 1 Due to the shape of the bay window door You must also open the left hand side flap before attempting to open the door 3 Ensure the...

Страница 11: ...thermocouple Air in gas line Pilot flame dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pres...

Страница 12: ...Code ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap Millivolt Terminals Pilot Adjus...

Страница 13: ...e is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a properly grounded three prong receptacle DO NOT cut or remove the grounding prong...

Страница 14: ...THE BLOWER 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burners Lift the tray out 3 Remove t...

Страница 15: ...d by S I T STEP 5 To change the pilot orifice First remove the two 2 T 20 Torx screws that hold the pilot assembly to the burner tray Lift the pilot assembly from the burner tray Using a 10mm wrench d...

Страница 16: ...dealer Serial number of the appliance Nature of complaint defect or malfunction Description and part of any parts replaced To the Distributor Sign and verify that the work and information is correct T...

Страница 17: ...Long EG28 150 Ash Sill EC 025 Burner Switch for Nova Tray EG28 161 Door Hinge Brackets EC 029 Fan Access Cover Gasket EG28 162 Door Latch Bracket 50 512 Convection Blower EG28 169 BV 4 Crimped Flue Co...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ..._____ Name of Installer ___________________________________________ Address _______________________________________ ___________________________________________ ________________________________________...

Отзывы: