background image

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY 

THIS MANUAL IS PRINTED ON RECYCLED PAPER

 

 

 

 

 

 

 

 

 

 

EG 28 B Vented 

                B y  

S H E R W O O D  

I N D U S T R I E S  

O W N E R S   M A N U A L  

 
 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

WHAT TO DO IF YOU SMELL GAS 

 Open windows 

 Do not try to light any appliance. 

 Do not touch any electrical switch; do not use any phone 

in your building. 

 Immediately call your gas supplier from a neighbor's 

phone.  Follow the gas supplier's instructions. 

 If you cannot reach your gas supplier, call the fire 

department. 

WARNING

 

If the information in this manual is 

not followed exactly, a fire or 

explosion may result causing 

property damage, personal injury 

or loss of life installation and 

service must be performed by a 

qualified installer, service agency 

or the gas supplier. 

FOR YOUR SAFETY 

Do not store or use gasoline or other 

Flammable

 vapors and liquids in the vicinity of 

this or any other appliance. 

Massachusetts installations

 (WARNING): 

This product must be installed by a licensed plumber or gas fitter when installed within the 

Commonwealth of Massachusetts. Other Massachusetts code requirements: Flexible connector must not be longer than 36”, shutoff valve 
must be a “T” handle gas cock, only direct vent sealed combustion products are approved for bedroom/bathrooms, fireplace dampers must 
be removed or welded in the open position prior to the installation of a fireplace insert or gas log. 

Содержание EG 28 B

Страница 1: ...esult causing property damage personal injury or loss of life installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use...

Страница 2: ...tion must conform to local codes or in the absence of local codes with the current CAN CGA B149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA To prevent inju...

Страница 3: ...d for use with either natural or propane gases See control panel and rating label Are not for use with solid fuels Must not be connected to a chimney flue serving a separate solid fuel burning applian...

Страница 4: ...the flue system of the stove can be properly installed without damaging the integrity of the building e g cutting a wall or ceiling joist The stove can be installed on any standard flooring materials...

Страница 5: ...within 3 feet 90cm horizontally from the center line of the regulator I Clearance to service regulator vent outlet 6 feet 1 8m minimum J Clearance to non mechanical air supply inlet to building or the...

Страница 6: ...CING A SEPARATE SOLID FUEL BURNING APPLIANCE FLUE GAS SPILL SWITCH NOTE THIS HEATER MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM THIS HEATER IS EQUIPPED WITH A VENT SAFETY SHUTOFF SYSTEM DESIGNED TO...

Страница 7: ...te provincial codes regarding the suitability of your application For other special venting requirements please refer to the local state provincial or national codes For best venting performance we re...

Страница 8: ...ition to insure safe optimum operating conditions 1 Open the front door 2 Place each piece of the log set into the firebox resting the pins in the holes in the logs 3 Close the door and tighten secure...

Страница 9: ...f all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the fl...

Страница 10: ...will expose a door fastener Using a 1 2 wrench loosen the fastener 1 Due to the shape of the bay window door You must also open the left hand side flap before attempting to open the door 3 Ensure the...

Страница 11: ...thermocouple Air in gas line Pilot flame dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pres...

Страница 12: ...Code ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap Millivolt Terminals Pilot Adjus...

Страница 13: ...e is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a properly grounded three prong receptacle DO NOT cut or remove the grounding prong...

Страница 14: ...THE BLOWER 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burners Lift the tray out 3 Remove t...

Страница 15: ...d by S I T STEP 5 To change the pilot orifice First remove the two 2 T 20 Torx screws that hold the pilot assembly to the burner tray Lift the pilot assembly from the burner tray Using a 10mm wrench d...

Страница 16: ...dealer Serial number of the appliance Nature of complaint defect or malfunction Description and part of any parts replaced To the Distributor Sign and verify that the work and information is correct T...

Страница 17: ...Long EG28 150 Ash Sill EC 025 Burner Switch for Nova Tray EG28 161 Door Hinge Brackets EC 029 Fan Access Cover Gasket EG28 162 Door Latch Bracket 50 512 Convection Blower EG28 169 BV 4 Crimped Flue Co...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ..._____ Name of Installer ___________________________________________ Address _______________________________________ ___________________________________________ ________________________________________...

Отзывы: