Maintenance And Service
R
emoVing
/R
epLacing
c
onVection
f
an
:
The fan assembly can be removed to access the convection blower.
1. Use a T-20 screwdriver to remove the screws that hold the Fan Mounting Plate in place See Figure 21.
2. Tilt the assembly back and pull it away from the unit.
3. The Fan is removed from the Mounting Plate by removing the six (6) screws that hold it in place
using a T-20 screwdriver.
4. The fan can then be disconnected from the wiring harness (See Figure 22 for fan wiring).
5. To replace fan, follow steps 1-4 in reverse order.
Figure 21: Fan Mount Removal.
Temperature Sensor
Convection Blower
FCM
Ground
Green
Black
Black
White
Figure 22: Fan Wiring.
17