Web: Profile Editor

 

Create  a  new  profile  or  edit  an  existing  one  using  the 

profile-editor. Profile Editor opens in a new page in your 

web browser. Select a module on the left and the right 

panel  will  provide  help  about  that  panel.  Connect  a 

module to another using wires from one point to another.

 

The direction of the wire (arrow) is important, the arrow 

signifies output, and reflects the flow of data.

 

Web: Profile Modules

 

Each  profile  is  made  up  of  two  or  more  connected 

Modules  or  Actions.  The  relationship  between  them 

forms the layout of the data flow within the profile.

 

The following modules are available:

 

The 

PLink  1U

  module  represents  one  of  the  physical 

ports on the rear of this unit, and maps to 1 Universe.

 

 

Protocol:  select  the  led  protocol  that  the  pixel 

tape conforms to.

 

 

Ordering:  RGB or  RGBW  mapping  that  the  pixel 

tape conforms to. RGB modes use 3 DMX slots per 

LED pixel, and RGBW modes use 4 DMX slots.

 

 

Grouping:  it  allows  one  DMX  pixel  to  drive 

multiple physical LED pixels  

 

 

Start-Ch:  DMX Start Channel for the 1

st

 pixel can 

be changed as needed.

 

Limitation

: Same  PLink port# cannot  be  re-used  within 

the same profile

 

 

The 

PLink  2U

  module  represents  one  of  the  physical 

ports on the rear of this unit, and maps to 2 Universe.

 

 

Each PLink 2U module has 2 input nodes that can 

be connected to two Ethernet streams. Top one 

(U1) is mapped to the First universe and Bottom 

one  (U2)  is  mapped  to  the  Second  universe 

relative to the pixel-tape.

 

 

Protocol:  select  the  led  protocol  that  the  pixel 

tape conforms to.

 

 

Ordering:  RGB or  RGBW  mapping  that  the  pixel 

tape conforms to.

 

 

Limitation

: Same  PLink port# cannot  be  re-used  within 

the same profile

 

 

Art-Net Stream: 

"Send IP address": is the  destination 

address used when the stream is sending data only.

 

 

 

ESP Stream

: ENTTEC Show protocol DMX over Ethernet 

stream (ESP).

 

IP  address  is  the  destination  address  used  when  the 
stream is sending data only. 

 

 

 

Kinet Stream

: For example: You can connect Kinet Stream 

to an Art-Net Stream to convert and output as Art-Net. (Kinet 
stream is supported as input only)

.

 

 

 

 

Streaming ACN

: "IP address" is the destination address 

used  when  the  stream  is  sending  data  only

  

(default is disabled = 0.0.0.0) 

 

 

DMX Generator

: Define your own custom DMX Channel 

values and assign the selected ones.

 

Snapshot feature can be used to capture values from an 
input  stream.  All  modifications  can  be  done  using  the 

DMX Grid Page.

 

Содержание Pixelator 70060

Страница 1: ...so we can update our documentation Physical Dimensions Note All dimensions are in millimetres unless specified otherwise Features 24 Pixel Link RJ 45 ports data output only Superfast Gigabit ethernet...

Страница 2: ...d verify that it looks to be in good condition before plugging it in to power 2 The Pixelator occupies a single unit 1U in a 19 inch rack You may attach it to the rack either at this time or later aft...

Страница 3: ...n the screen and activating the option The Top Bottom button are used to navigate scroll through the options on any screen The currently selected option is highlighted with a white background on the s...

Страница 4: ...couple of screens and the LCD Main Menu will only be visible once the system is fully ready usually takes a minute System Restarting Please wait Web Interface The Pixelator is configured controlled a...

Страница 5: ...ed as needed Limitation Same PLink port cannot be re used within the same profile The PLink 2U module represents one of the physical ports on the rear of this unit and maps to 2 Universe Each PLink 2U...

Страница 6: ...or s web browser page under the Settings section Note While the firmware is being updated please do not power off the unit please wait until the web page is processing up to 5 minutes If the web page...

Страница 7: ...asy to hide design High power screw terminal connectors Easy wiring using straight Cat5 Cat6 standard connections Notes Plink system only works with CAT5 6 straight through cables do not use crossover...

Страница 8: ...improvements and innovations of all ENTTEC products specifications and features are subject to change without notice Registration Please register your ENTTEC product to get latest software updates and...

Отзывы: