Once EMU finds the OCTO, you will be able to open the device webpage and configure it.

 

Factory Reset the device using the reset button if the above steps do not resolve the issue.

 

The  OCTO  MK2’s  factory  default  resets  the  OCTO  MK2  to  static  IP  address  192.168.0.10  and  Netmask 

255.255.255.0 with DHCP enabled. 

 

When the OCTO MK2 has DHCP enabled but DHCP server is unavailable (e.g. the device is connected to a 

computer without DHCP server), the IP address will fall back to 192.168.0.10 with netmask 255.255.255.0.  

 

What if my LED strip protocol is not in drop down list? How to add new LED strip 

protocol to OCTO MK2? 

The OCTO MK2 allows the user to choose a pixel output protocol even it is not found in the drop-down list. 

 

Visit  the  ENTTEC  Website  to  view  the  ‘OCTO  MK2  Custom  Protocol  Creation  Guide’  document  for  more 

information about the key criteria and the step-by-step custom protocol creation guide.

 

What is the minimum DC voltage for powering the OCTO MK2? 

The minimum DC voltage the OCTO MK2 requires to run is 5V.  

 

Servicing, Inspection & Maintenance 

 

The device has no user serviceable parts. If your installation has become damaged, device should be 

replaced.

 

 

Power down the device and ensure a method is in place to stop the system from becoming energized 

during servicing, inspection & maintenance.

 

Key areas to examine during inspection:

 

 

Ensure all connectors are mated securely and show no sign of damage or corrosion.

 

 

Ensure all cabling has not obtained physical damage or been crushed.

 

 

Check for dust or dirt build up on the device and schedule cleaning if necessary.

 

 

Dirt or dust build-up can limit the ability for a device to dissipate heat and can lead to damage.

 

The replacement device should be installed in accordance with all steps within the installation guide.

 

To order replacement devices or accessories contact your reseller or message ENTTEC directly.

 

Cleaning 

Dust and dirt build up can limit the ability for the device to dissipate heat resulting in damage. It’s important 

that the device is cleaned in a schedule fit for the environment it is installed within to ensure maximum 

product longevity.

 

Cleaning schedules will vary greatly depending on the operating environment. Generally, the more extreme 

the environment, the shorter the interval between cleaning.

 

 

 

Before cleaning, power down your system and ensure a method is in place to stop the system from 

becoming energized until cleaning is complete.

 

 

 

Do not use abrasive, corrosive, or solvent-based cleaning products on a device.

 

 

Do not spray device or accessories. The device is an IP20 product. 

 

Содержание 71521

Страница 1: ...Document Updated October 2022 OCTO MK2 71521 User Manual 8 universes eDMX to LED pixel smart controller with network chaining in a compact 4 module DIN rail form factor...

Страница 2: ...dentify Reset Button 8 Out of the Box 8 Networking 8 Web Interface 8 Top Menu 9 Home 9 Settings 10 Network Stats 12 Help 13 Updating Firmware 13 Reset to Factory Defaults 13 Resetting via Web Interfac...

Страница 3: ...nts of all connected devices and factor in overhead as well as verifying that it is appropriately fused and voltage is compatible Remove power from your installation immediately if accessories power c...

Страница 4: ...ling ENTTEC products Once installation is completed check that all hardware and components are securely in place and fastened to supporting structures if applicable Installation Safety Guidelines The...

Страница 5: ...voltage or Electro Magnetic Interference EMI being induced on the control signal lines where possible run control cabling away from mains electricity or devices that produce high EMI i e air conditio...

Страница 6: ...bsite for the latest version USER MANUAL 6 ID 5928937 Document Updated October 2022 Mounting Options Note The surface mount tabs have been designed to hold the weight of the OCTO MK2 only excess force...

Страница 7: ...xel Hardware Features Electrically insulated ABS plastic housing Forward facing LED status indicator Identify Reset button Pluggable terminal blocks Link Activity LED indicator built into both RJ45 po...

Страница 8: ...5 0 If a DHCP address is provided this can be used to communicate with the OCTO MK2 Static IP By default out of the box the Static IP address will be 192 168 0 10 If the OCTO MK2 has DHCP disabled the...

Страница 9: ...and be within the same IP address range as the OCTO MK2 For example if your OCTO MK2 is on Static IP address 192 168 0 10 Default then your computer should be set to something such as 192 168 0 20 It...

Страница 10: ...OCTO MK2 provides more than 20 output pixel protocols listed below APA 102 APA 104 SPXL 16bit 8bit SK6812 TM1804 TM1812 TM1814 UCS1903 UCS2903 UCS2904 UCS8903 16bit 8bit UCS8904 16bit 8bit WS2811 WS2...

Страница 11: ...ts can be assigned a universe number in the range 1 63999 Please note the OCTO MK2 supports a maximum of 1 multicast universe with sACN sync i e all universes set to the same value ESP Outputs can be...

Страница 12: ...ows the OCTO MK2 reset back to factory default via web interface Please refer to the Reset to Factory Defaults section of this document Reboot Please allow up to 10 seconds for the device to reboot Wh...

Страница 13: ...ate Firmware mode It may take a while depending on the network setting This mode will display basic information regarding the device including current Firmware Version Mac Address and IP address infor...

Страница 14: ...pear as shown in the image below Resetting by Reset Button The reset button on the device restores the network configuration of the OCTO MK2 to factory defaults To reset to factory defaults the follow...

Страница 15: ...become damaged device should be replaced Power down the device and ensure a method is in place to stop the system from becoming energized during servicing inspection maintenance Key areas to examine...

Страница 16: ...ow you to determine a reliable cleaning schedule for your installation Package Content OCTO MK2 2 WAGO connectors 1 Din mounting clip screws 1 ELM Promo Code 8 Universes on device s sticker Revision H...

Отзывы: