Page 51
[
;!:!
] = [
##
]
TEMPERATURE LIMIT SWITCH OR WFS
PROCESS OUTPUT - When
[
;!:!
]
=[
##
], the valve 3 output will be
on when the TEMPERATURE LIMIT SWITCH
input TLS1 is open
.
[
;!:!
] = [
#$
]
CURRENT OUTSIDE LIMIT FLASH HI or LO
PROCESS OUTPUT - When
[
;!:!
]=[
#$
], the data display will
flash HI or LO when the control is unable
to keep the
current constant within the programmed
HI or LO windows
limits.
[
;!:!
] = [
#%
]
CURRENT OUTSIDE LIMIT FLASH HI or LO
PROCESS OUTPUT - When
[
;!:!
]=[
#%
], the four digit data display will
flash HI or LO when the control is unable
to keep the current constant within the window limits programmed in HI or LO
windows
; In addition, the valve 3 output will turn
ON
for 0.5 second.
[
;!:!
] = [
#&
]
CURRENT OUTSIDE LIMIT FLASH HI or LO
PROCESS OUTPUT - When
[
;!:!
]=[14], the data display will
flash HI or LO when the control is unable to keep
the current constant within the window limits programmed in HI or LO
. In addition,
the CONTROL will
stop a repeat or chained sequence and put the control in NO
WELD, after the weld in which the error occurs
. If a sequence is interrupted, the front
panel will flash HI/LO message until the operator presses any push-button. After clearing
error message on the front panel, WELD/NO WELD push-button must be pressed in
order to put Control back in WELD mode.
This Process Output does not use Valve 3
for error indication. See
[
;!:!
]=[27]
if Valve 3 is required.
[
;!:!
] = [
#'
]
HARDWARE ERROR / CONTROL RELAY
PROCESS OUTPUT - When
[
;!:!
]
=[
#'
], the valve 3 output will turn
ON if a Control Board error is detected.
[
;!:!
] = [
#(
]
ERROR [
0!X!
]=26 INDICATION
PROCESS OUTPUT - When
[
;!:!
]
= [
#(
], the valve
3 output will turn
ON
if shorted SCR or L2 missing
error
, [
0!X!
]=26
, is detected
.
[
;!:!
] = [
#)
]
SEVERAL ERROR INDICATION
PROCESS OUTPUT - When
[
;!:!
]
= [
#)
], the
Valve 3 output will turn
ON if following errors are detected:
TLS error, EEPROM
error, AVC errors, during End of Stepper message in stepper modes, etc.
[
;!:!
] = [
#*
]
ERROR [
0!X!
]=13 INDICATION
PROCESS OUTPUT - When
[
;!:!
]
= [
#*
], the Valve
3 output will be
ON
if full SCR conduction
error
, [
0!X!
]=13
, is detected
.
[
;!:!
] = [
#+
]
With this Process Output, Valve 3 will be ON during the WELD time of the sequence,
only in WELD mode and closed NW1-GND input on TS1. This PO is the same as
[
;!:!
]= 01, except that Valve 3 will not be ON if Control is in NO WELD mode or if
NW1-GND input on TS1 is open.
[
;!:!
] = [
$$
]
- Used with RS232 or RS485 Option - EN1001
ONLY
.
This Process Output will prepare Error Code and Current to be sent to master on ENBUS
or to Serial Printer:
Current in [%] or [kA] after end of weld if current was within limits. Error message
0!X!3O
if current was above maximum limit and current value in [%] or [kA]. Error
message
0!X!7U
if current was below min. limit and current value in [%] or [kA].
StockCheck.com
Содержание EN1000 series
Страница 2: ...S t o c k C h e c k c o m ...
Страница 19: ...Page 17 Figure 3 6 External SCR Contactor connection S t o c k C h e c k c o m ...
Страница 120: ...Page 118 11 3 TROUBLESHOOTING GUIDE S t o c k C h e c k c o m ...
Страница 121: ...Page 119 S t o c k C h e c k c o m ...
Страница 122: ...Page 120 11 4 BLOCK DIAGRAM S t o c k C h e c k c o m ...