2.1 CONTROL FUNCTIONS - Continued
- See Figure 1, CONTROL PANEL
LAYOUT (Page 6)
WELD LIGHT
(23)
- The white WELD lamp on the dial plate, is connected directly across
the welding transformer and will light when voltage is present at the welding transformer.
The brilliance of the white WELD lamp is an indication of the programmed PERCENT
CURRENT and therefore provides a visual indication of the percent of RMS voltage
supplied to the welding transformer.
SCHEDULE DISPLAY
(22)
- The SCHEDULE DISPLAY shows the number of the
active SCHEDULE. The EN1000/EN1001 can store up to 50 schedules [ 00 to 49 ].
SCHEDULE PUSH-BUTTONS
(20) & (21)
- The
right
button
increments
SCHEDULE
by
one
, and the
left
button
increments
SCHEDULE by
ten
. When either digit reaches the
maximum, it resets to zero.
There are two ways to select the active SCHEDULE:
1.
INTERNAL
: Use the
SCHEDULE
push-buttons and
select
the desired
SCHEDULE.
Initiation on FS3 to GND will select the schedule shown in the display. See
EXTENDED FUNCTIONS Section 5.4.3 - [
=!=!
] = 00.
2.
EXTERNAL
: Use a combination of FS7/SS1 AND FS11/SS3 to
select one of four
schedules
. See EXTENDED FUNCTIONS section 5.4.3. - [
=!=!
] = 01.
PROGRAM/OPERATE PUSH-BUTTON
(26)
- will put the control in the PROGRAM
or OPERATE mode. LED indicators (25) and (27) indicate which mode the control is in.
PROGRAM mode is the mode in which the individual schedules can be entered or modified.
DATA such as weld time, percent of current, valve select, etc. can only be changed in
the PROGRAM MODE
.
OPERATE mode is the normal operating mode for the control. This is the only mode in
which the control can be initiated for a weld. When the control is in OPERATE mode, the
control is in a "Ready" (to initiate) state.
PROGRAM LOCKOUT SWITCH (24)
(Optional)
A PROGRAM LOCKOUT key switch can be ordered as a factory installed option. It may
also be added later by the customer, if desired. To install the key switch, remove the key
switch hole-plug from the cabinet and mount the switch using the nut and lock-washer
provided. Connect the plug from the switch onto the mating 2-prong connector (J1) on the
back of the display circuit board.
To put the control in the
PROGRAM
mode using the PROGRAM LOCKOUT Switch:
Rotate the key 45 degrees clockwise and hold, while holding the key in this
position, press and release the PROGRAM/OPERATE push-button
, then release
the key. The OPERATE LED will now turn off and the PROGRAM LED will turn
on, indicating programmability of all functions.
To put the control back in the
OPERATE
mode:
Press the PROGRAM/OPERATE push-button again. The control will return to the
OPERATE Mode without the necessity of rotating the key.
NOTE:
See Section 5.4.17 for detailed information on PIN Lockout Mode.
StockCheck.com
Содержание EN1000 series
Страница 2: ...S t o c k C h e c k c o m ...
Страница 19: ...Page 17 Figure 3 6 External SCR Contactor connection S t o c k C h e c k c o m ...
Страница 120: ...Page 118 11 3 TROUBLESHOOTING GUIDE S t o c k C h e c k c o m ...
Страница 121: ...Page 119 S t o c k C h e c k c o m ...
Страница 122: ...Page 120 11 4 BLOCK DIAGRAM S t o c k C h e c k c o m ...