J1
Visualization mode. It is only possible to visualize the values and
parameters present.
Maintenance mode. It is possible to visualise and modify the values
and parameters present.
The entry in maintenance mode is indicated by the permanent
switching on of the right-hand point.
J2
FUTURE USE
Make the electrical connections as shown in the figure.
The MD1-MD2 display module has a housing for a plug-in card, such as GOLR radio receiver. If present, the GOLR radio receiver
must be installed on the MD1-MD2 display module.
0
12
1
22
0
12
1
22
CONTROL
PANEL
J1
J2
max 50 m (shielded cable)
Green
Yellow
Brown
White
UP
DOWN
ESC
ENTER
RDX
GOLR
PPC2
ANT
BIXMR2
4. Electrical
connections
4.1 Use method selection
WARNING: after having connected the display module to the control panel, turn on the power and wait 30 s for autocon-
figuration of the display module and recognition of the automation.
WARNING: the plug-in cards must be inserted and removed with the power supply disconnected.
WARNING: do not connect storage modules BIXMR2 or BIXMR.