IP1938EN - 2017-12-07
-
use the keys
Ÿ
and
ź
to select the required function
-
press the ENTER key to confirm
Display
Application
Description
BE - Advanced battery test enabling.
OF - Disabled
ON - Enabled
The advanced battery test checks correct operation of the battery kit installed on
the automation.
EL21
BT - Selecting the battery mode.
00 - Anti-panic batteries with emergency opening.
01 - Continuity batteries with last opening operation.
02 - Continuity batteries with last closing operation.
LB - Signalling of flat batteries.
00 - Display
LB - Signalling of flat batteries.
00 - Display
01 - QIKLUX light kit
LL - Setting the flat batteries signalling voltage threshold. [V] (FUTURE USE)
NOTE: adjustment occurs with a sensitivity interval of 0.5 V, indicated by the
switching on of the right-hand point.
MIN
MAX
BD - Setting the batteries disconnection voltage threshold. [V]
NOTE: adjustment occurs with a sensitivity interval of 0.5 V, indicated by the
switching on of the right-hand point.
MIN
MAX
ES - Accessory power supply disconnection with automation stopped or in stand-
by mode. (FUTURE USE)
6.7 Second level menu - EM (Energy Management)
NOTE: adjustment occurs with a sensitivity interval of 0.5 V, indicated by the
switching on of the right-hand point.
NOTE: adjustment occurs with a sensitivity interval of 0.5 V, indicated by the
switching on of the right-hand point.
i
i
EM
i
NOTE: it is possible that, owing to the type of automation and control panel, certain menus are not available.