show policy rule
SecureStack C3 Configuration Guide
11-7
Defaults
If
verbose
is
not
specified,
summary
information
will
be
displayed.
Mode
Switch
command,
read
‐
only.
Example
This
example
shows
how
to
display
policy
classification
information
for
Ethernet
type
2
rules
C3(su)->show policy rule ether
|PID |Rule Type |Rule Data |Mk|PortStr |RS|ST|VLAN|CoS |U|
|02 |Ether |2048 (0x0800) |16|All | A|NV|fwrd| |?|
|02 |Ether |2049 (0x0801) |16|All | A|NV|drop| |?|
|02 |Ether |2989 (0x0bad) |16|All | A|NV|drop| |?|
|02 |Ether |33079 (0x8137) |16|All | A|NV|drop| |?|
This
example
shows
how
to
display
policy
classification
information
for
administrative
rule
1
C3(su)->show policy rule admin-pid 1
|Admin|Rule Type |Rule Data |Mk|PortStr |RS|ST|dPID|aPID|U|
tcpsourceport
Displays
TCP
source
port
rules.
udpdestport
Displays
UDP
destination
port
rules.
udpsourceport
Displays
UDP
source
port
rules.
data
Displays
rules
for
a
predefined
classifier.
This
value
is
dependent
on
the
classification
type
entered.
Refer
to
Table 11
‐
3
for
valid
values
for
each
classification
type.
mask
mask
(Optional)
Displays
rules
for
a
specific
data
mask.
Refer
to
Table 11
‐
3
for
valid
values
for
each
classification
type
and
data
value
.
port
‐
string
port
‐
string
(Optional)
Displays
rules
related
to
a
specific
ingress
port.
rule
‐
status
active
|
not
‐
in
‐
service
|
not
‐
ready
(Optional)
Displays
rules
related
to
a
specific
rules
status.
storage
‐
type
non
‐
volatile
|
volatile
(Optional)
Displays
rules
configured
for
either
non
‐
volatile
or
volatile
storage.
vlan
vlan
(Optional)
Displays
rules
for
a
specific
VLAN
ID.
drop
|
forward
Displays
rules
based
on
whether
matching
packets
will
be
dropped
or
forwarded.
dynamic
‐
pid
dynamic
‐
pid
Displays
rules
associated
with
a
specific
dynamic
policy
ID.
cos
cos
(Optional)
Displays
rules
for
a
Class
‐
of
‐
Service
value.
(Not
supported
on
B3,
C3,
G3
devices.)
admin
‐
pid
admin
‐
pid
Displays
rules
associated
with
a
specific
administrative
policy
ID
[1..1023].
‐
verbose
(Optional)
Displays
detailed
information.
usage
‐
list
(Optional)
If
selected,
each
rule
ʹ
s
usage
‐
list
shall
be
checked
and
shall
display
only
those
ports
which
have
applied
this
rule.
display
‐
if
‐
used
(Optional)
Displays
rule(s)
only
if
they
are
applied
to
at
least
one
port.
Содержание SECURESTACK C3
Страница 2: ......
Страница 34: ...xxxii...
Страница 40: ...Getting Help xxxviii About This Guide...
Страница 126: ...clear license 4 6 Activating Licensed Features...
Страница 132: ...set port inlinepower 5 6 Configuring System Power and PoE...
Страница 228: ...clear port protected name 7 60 Port Configuration...
Страница 270: ...clear snmp interface 8 42 SNMP Configuration...
Страница 396: ...clear port txq 12 10 Port Priority Configuration...
Страница 414: ...ip igmp robustness 13 18 IGMP Configuration...
Страница 542: ...clear arpinspection statistics 17 32 DHCP Snooping and Dynamic ARP Inspection...
Страница 546: ...Enabling Router Configuration Modes 18 4 Preparing for Router Mode...
Страница 640: ...traceroute ipv6 21 10 IPv6 Management...
Страница 698: ...show ipv6 dhcp binding 24 20 DHCPv6 Configuration...
Страница 746: ...show ipv6 ospf virtual link 25 48 OSPFv3 Configuration...
Страница 834: ...ip access group 26 88 Authentication and Authorization Configuration...
Страница 848: ...TACACS Configuration clear tacacs interface 27 14...
Страница 866: ...sFlow Configuration show sflow agent 28 18...
Страница 872: ...Index 4...