Setting the Mode Switches
B-2 Mode Switch Bank Settings and Optional Installations
Setting the Mode Switches
Figure B
‐
1
through
Figure B
‐
3
show
the
location
of
the
mode
switches
and
the
switch
settings
for
normal
operation.
These
switches
are
set
at
the
factory
to
the
off
position
and
rarely
need
to
be
changed.
Switch
definitions
and
positions
are
as
follows:
•
Switches
1
through
6
–
For
Enterasys Networks
use
only.
•
Switch
7
–
Clear
Persistent
Data.
Changing
the
position
of
this
switch
clears
Persistent
Data
on
the
next
power
‐
up
of
the
module.
All
user
‐
entered
parameters,
such
as
the
IP
address,
module
names,
etc.,
are
reset
to
the
factory
default
settings.
Once
the
module
resets,
you
can
either
use
the
factory
default
settings
or
reenter
your
own
parameters.
•
Switch
8
–
Clear
Admin
Password.
Changing
the
position
of
this
switch
clears
the
admin
password,
and
restores
the
factory
default
password
on
the
next
power
‐
up
of
the
module.
Once
the
module
resets,
you
can
either
use
the
factory
default
settings
or
reenter
your
own
password.
Caution:
Read the appropriate sections to be fully aware of the consequences when
changing switch settings.
Only qualified personnel should change switch settings.
Precaución:
Si desea modificar la configuración del interruptor, lea las secciones
correspondientes para saber cuál será el resultado de hacerlo.
Estas modificaciones a la configuración sólo debe realizarlas personal calificado.
Note:
Do not change the position of Switch 8 unless it is necessary to reset the admin
password to its factory default setting.