Overview of DFE Module Shutdown Procedure
Matrix DFE-Diamond Series Installation Guide 4-5
Overview of DFE Module Shutdown Procedure
The
DFE
modules
installed
in
a
Matrix
E7,Matrix
N1,
Matrix
N3,
Matrix
N5,
or
Matrix
N7
chassis
are
interdependent
and
operate
under
a
single
IP
address
as
a
single,
distributed
switch
system
(hardware,
databases,
and
persistent
storage).
In
this
operating
environment,
the
DFE
module
must
shut
down
in
an
orderly
fashion
to
ensure
that
the
other
modules
in
the
system
and
other
devices
on
the
network
are
notified
of
the
impending
change.
The
device(s)
can
then
make
intelligent
decisions
and
stabilize
the
network
before
the
change
is
made;
thereby
increasing
network
availability.
You
can
shut
down
a
DFE
module
in
an
operating
system
using
the
OFFLINE/RESET
switch
shown
in
Figure 4
‐
2
.
There
are
two
procedures
to
shut
down
a
DFE
module.
•
Recommended
shutdown
procedure
(“
Recommended
Shutdown
Procedure
”
on
page 4
‐
6)
•
Last
resort
shutdown
procedure
(not
recommended)
(“
Last
Resort
Shutdown
Procedure
”
on
page 4
‐
7)
User parameters
(IP address, device
and module name,
etc.) were lost
when the module
power was cycled,
the front panel
RESET button was
pressed.
Position of Mode switch (7),
Persistent Data Reset, was
changed sometime before
either cycling power or
pressing the RESET button,
causing the user-entered
parameters to reset to factory
default settings.
Clear Persistent Data that
was set through Local
Management.
The module was moved
either from slot-to-slot or from
chassis-to-chassis.
Reenter the lost parameters as necessary. Refer
to the
Enterasys Matrix DFE-Diamond/Platinum
Series Configuration Guide
for the instructions to
configure the device.
If the problem continues, contact
Enterasys Networks for technical support.
Table 4-2 Troubleshooting Checklist (continued)
Problem
Possible Cause
Recommended Action
Caution:
Do not remove a DFE-Diamond module from an operating chassis system before reading
the following information and instructions.
Precaución:
Antes de retirar los módulos DFE-Diamond del chasis en funcionamiento, lea las
siguientes instrucciones y la información suministrada.
Содержание Matrix 7GR4202-30
Страница 2: ......
Страница 14: ...xii...
Страница 30: ...XENPAK 10 Gigabit Ethernet 2 4 Network Requirements...
Страница 58: ...Completing the Installation 3 28 Installation...
Страница 66: ...Last Resort Shutdown Procedure 4 8 Troubleshooting...
Страница 74: ...Regulatory Compliance A 8 Specifications...
Страница 84: ...Memory Locations and Replacement Procedures B 10 Mode Switch Settings and Installing Options...