The encoding used by the TEMP SENSOR bit field is shown in Table 33 below.
TEMP SENSOR
Reporting interval reduction based on temperature
0b00 (Default)
Disabled (No reporting interval reduction)
0b01
Enabled, Reporting interval reduction if temperature below threshold
0b10
Enabled, Reporting interval reduction if temperature above threshold
0b11
Reserved (Do not use)
Table 33
–
TEMP SENSOR bit field encoding
The encoding used by the HUMIDITY SENSOR bit field is shown in Table 34 below.
HUMIDITY SENSOR Reporting interval reduction based on temperature
0b00 (Default)
Disabled (No reporting interval reduction)
0b01
Enabled, Reporting interval reduction if humidity below threshold
0b10
Enabled, Reporting interval reduction if humidity above threshold
0b11
Reserved (Do not use)
Table 34
–
HUMIDITY SENSOR bit field encoding