Code: I.H4.V10.3003
Installation and Maintenance Manual
Version: 07
18 / 66
Ennera Energy and Mobility, S.L.
This document contains confidential information which is property of Ennera Energy and Mobility, S.L. The copy, transmission or use by other people, of the whole document or
part of its contents, is not allowed without written permission from Ennera Energy and Mobility S.L.
3.
Put the ground anchor (EL-1) on the
fixing point with an angle of around 45º
(pointing to the tower) and hit it on the
top with a hammer before start
screwing.
4.
With a metal rod (EL-2) inserted in
the ground anchor (EL-1) eye, start
screwing as shown in the figure.
5.
After screwing the only visible part
of the ground anchor should be the eye.
6.
Connect the sections of the ginpole
(EL-6) with 4 M10x40 screws.
7.
Place the ginpole on the tower as
shown in the figure.
The ginpole is heavy, be
careful transporting it.
8.
Fix the ginpole (EL-6) to the tower
base (T1) with a M20x180 screw (EL-8).
EL-1
EL-2
EL-6
EL-8