background image

ENIGMA II DR-81000 Digital Receiver

Version 2.00

Removing and Installing Cards

The   receiver   does   not   have   to   be   powered   down 
while   components   of   the   system   are   removed   or 
installed.

CPM2 Card

Remove the 4 retaining screws on the back panel of 
the   Card.   Carefully   pull   the   Card   out   of   the   rack 
housing. Installation is the reversal of removal. Push 
the Card carefully and firmly back to its place, then 
mount   the   retaining   screws.   After   plugging   in,   the 
CPM Unit will make a cold start.

LC2 Line Cards 

Remove the 2 retaining screws on the back panel of 
the   Card.   Carefully   pull   the   Card   out   of   the   rack 
housing. Installation is the reversal of removal.

RC2 Radio Card

Remove the 4 retaining screws on the back panel of 
the   Card.   Carefully   pull   the   Card   out   of   the   rack 
housing. Installation is the reversal of removal. If you 
install   a   new   RC2   card,   please,   remove   the   blank 
cover of the radio card slot first.

Note, that there is a dedicated position for the PWR, CPM  
and RC cards, which cannot be installed in other positions. 
Also,   for   the   LC   cards,   the   actual   Line   Card   number  
depends   on   the   position   the   Line   Card   installed   into.   If  
possible, please fill up the cards from right to left (1 to 8).

ENIGMA II Backplane View (Example)

11

Содержание DR-81000

Страница 1: ...ENIGMA II DR 81000 Digital Receiver User Manual CPM2 V2 20 build A430 LC2 V2 20 build A426 RC2 V2 11 build 9403 ...

Страница 2: ...with the default programming 7 Return to the default programming 7 3 Installation 8 Mounting the Receiver 8 Printer Connections 8 Computer Connections 8 Ethernet Connection 8 CPM Card Backplane Diagram 8 Telephone Line Connections 9 Grounding 9 Line Card Backplane Diagram 9 Power Supply Card 10 Power Supply Backplane Connections 10 Removing and Installing Cards 11 CPM2 Card 11 LC2 Line Cards 11 RC...

Страница 3: ...display mode 14 Protected Mode Operation 15 Entering Protected Mode 15 The Menu 16 Utilities 16 Report 16 Print 16 Reset 16 Setup 16 Options 16 Time Date 17 CPM2 Ports 18 Serial Ports COM A and COM B 18 Report Mode 18 Receive Mode 18 Program Mode 18 Port Setup 18 Serial Port Setup 18 Serial Protocols 20 Serial Port Status Display 22 USB Ports 22 Parallel Port 22 Printing 22 TCP IP Options 23 TCP S...

Страница 4: ...Setup 30 Line Card Status 31 7 RC2 Radio Card 33 General Information 33 Installation 33 RC2 Features 33 RC2 Operation 33 Radio Reception 33 CPM2 Supervision 34 Radio Card Menu 34 Audio Monitoring 34 RC2 Radio Card Settings 34 RC2 Card Status Display 35 8 Power Card 36 Inputs and Outputs 36 Power Status Display 36 Battery Testing 36 Appendices 37 Appendix A System Event Table 0000 37 Appendix B Sup...

Страница 5: ...ntification capability is built in and the telephone number of the calling party can be displayed printed stored in memory and forwarded to the automation computer The Line Cards also support the 2 way audio listen in The Line Cards are continuously supervised by the CPM Unit to ensure uninterrupted communication Any trouble conditions are immediately reported on the LCD screen and printer and or ...

Страница 6: ...xternal acknowledge and tamper supervision 2 Programmable Outputs on the CPM2 card IP Multiformat receiver CID E2 SIA Support for various IP GPRS communicators Full SIA IP Event Reporting DC 09 support Automatic ES 128 encryption support TCP Socket supervision keep alive support PSTN Multiformat receiver pulse DTMF FSK Caller ID capability Bellcore ETS and DTMF Telephone line supervision Contact I...

Страница 7: ...ry cables The CPM unit carries out a comprehensive Power on Self Test and tests all system components If the CPM finds any malfunctioning unreliable components during the POS test it will stop and display the problem on the screen After the POS test had been finished the CPM resets the line cards in system and will switch to event list mode normal operation Operation with the default programming W...

Страница 8: ...T Using parallel printer cable with only one common ground wire is not recommended Computer Connections Connect the automation computer to the ENIGMA II DR 81000 serial COM A port using the supplied cable or to USB A using the supplied miniUSB cable If the supplied cable is not long enough a serial Null modem cable can be used up to 15 meters in length and a longer miniUSB cable can also be used i...

Страница 9: ...PBX system 2 way audio communication needs bridging resistors with the same value as measured on the handset Using improper termination the line will be dropped when switched to 2 way Audio Mode Grounding To achieve the best resistance against static and electric noise and electromagnetic interference EMI connect the metal casing of the receiver to a grounding point Note that the grounding of the ...

Страница 10: ...er Card Connect the battery cables to the battery outputs with the supplied terminals Using a 7 Ah backup battery is recommended to avoid battery test problems It is very important to connect protective ground shielding to the grounding terminal on the back of the PWR card This ensures the protection against static discharge A standard M5 nut is provided at the earthing point for connection This p...

Страница 11: ... 2 retaining screws on the back panel of the Card Carefully pull the Card out of the rack housing Installation is the reversal of removal RC2 Radio Card Remove the 4 retaining screws on the back panel of the Card Carefully pull the Card out of the rack housing Installation is the reversal of removal If you install a new RC2 card please remove the blank cover of the radio card slot first Note that ...

Страница 12: ...eption in progress packet received while red light indicates transmission in progress packet sent in case repeater RX TX mode is enabled During Flash Update of the card the LED blinks slowly green 1 8 LEDs The LEDs 1 8 display status information of the line cards Continuous green light indicates standby mode the line is ok and the card is waiting for call Ring is signalled by fast blinking it turn...

Страница 13: ...ble event libraries 2 RS 232 serial ports COM A and COM B 2 USB 2 0 CDC A and B virtual serial ports 10 BaseT Ethernet interface Serial port data rates can be set from 300 to 57600 baud Serial port data protocol data bits parity programmable External acknowledge input 2 OC Programmable Outputs to follow different system status CPM2 Startup Sequence After power up the CPM2 waits for flash upgrade a...

Страница 14: ...eceived The line card numbers can be between 1 and 8 The two optional radio channels are represented by A and B System events are displayed with S and events received via the TCP IP port are shown with IP If there are more receivers linked together the line card numbers of the linked receivers are displayed with the extra character X added before them The fourth column contains the time of the eve...

Страница 15: ...ch Pressing a function key first will enter the first character assigned to it pressing it again shortly will enter the second assigned character and so on If the desired character is reached leaving the function key untouched for 2 seconds will finalize the character and the cursor will step onto the next position Pressing a different function key will also finalize the character Stepping back is...

Страница 16: ...ral station operator to make a full receiver reset This can be useful if receiver malfunctions encountered There are three different levels of system reset The Factory reset will reset the receiver parameters to default This option might be useful if the user has misprogrammed the unit and wants to return to the factory default state This option is protected Figure 7 The Reset Menu The Memory func...

Страница 17: ... if the connection on COM B is broken The default setting is printer off Link Mode As there are two independent serial ports are implemented on the receiver and both can be configured to report mode at the same time it is necessary to set when the link with the PC should be considered ok There are two options available here A OR B The link to the PC is considered good if there is connection in any...

Страница 18: ...als The heart beat signals are used to test the communication link between the receiver and the central station computer when there is no reportable event in the memory buffer In this case the receiver sends so called heart beat signals to the computer in a programmed time interval and requires acknowledge for that If the acknowledge is missing or negative it assumes that the computer is failed an...

Страница 19: ...s Here the asynchronous protocol for the serial port is set port speed number of databits and parity The port speed can be set between 300 and 57600 bps the number of databits can be set to 7 or 8 and the parity can be choosen as none even or odd The default setting is 9600 8 databits no parity NOTE The number of stopbits is always set to 1 This option is not changeable Receiver Number In multi re...

Страница 20: ...ledge it for verification 1RR0sssssssssss ssss DC4 Where 1 Protocol ID Basic Signal RR Receiver number Heart beat signal DC4 Terminator 014h SIA Level 1 Protocol The SIA Level 1 Protocol is used to forward events received in SIA format When multiple events are received in one SIA data block SIA level 2 and 3 and the receiver is programmed to split the block to individual messages then reports them...

Страница 21: ...iver is programmed to split the block to individual messages then reports them with this protocol SRRL AAAAAA EXXYYYY XXYYYY DC4 Where S Protocol ID RR Receiver number L Line Card ID Account ID code AAAAAA Account number Field separator XX SIA Event code or modifier YYYY Zone code user code time date info Data separator DC4 Terminator 014h Clock Signal Protocol The Clock Signal Protocol is used to...

Страница 22: ...t can be downloaded from www enigmareceiver com Parallel Port The CPM Unit has a 8 bit parallel port for printer connection Practically any printer with Centronics parallel interface can be connected to the port and can be used as the system printer If possible the use of a line printer is highly recommended as there is no such page buffering as with most page printers so that they can provide ins...

Страница 23: ...rt the receiver extends the socket timeout to its maximum automatically to preserve these sockets and providing a more stable connection on the GPRS network IP Based Reception The Enigma II receiver accepts identifies and decodes different kinds of incoming IP reports automatically For the list of supported IP reporting formats please refer to the E2 IP Support pdf file The receiver also handles e...

Страница 24: ...or both must be defined for a rule E g Name description Public Inbound Port TCP UDP Local Private IP Local Private Port IP komm TCP 9999 TCP 192 168 1 240 9999 IP komm UDP 9999 UDP 192 168 1 240 9999 This table is serves as an example only the names and expressions in this table can be vary for different kinds of routers The above setting will forward all incoming communications on port 9999 to th...

Страница 25: ...be modified here as well to support multiple receivers on the local network Name description Public Inbound Port TCP UDP Local Private IP Local Private Port Remote 1 2323 TCP 192 168 1 240 23 Remote 2 2333 TCP 192 168 1 241 23 This table is serves as an example only the names and expressions in this table can be vary for different kinds of routers With the above setup the remote management ports o...

Страница 26: ...onfiguration SIA level 3 with reverse channel restrictions Installation Up to 8 LC2 Line Cards can be installed in the Enigma II receiver The installation procedure of the Line Cards is described in Chapter 3 The actual line card number depends on which slot is the line card installed Positions 1 to 8 correspond to line card numbers 1 to 8 respectively LC2 Line Card Features High speed RISC microp...

Страница 27: ...y mode In stand by mode the Line Card monitors the telephone line and waits for calls from digital communicators If the card is operating normally the following will be displayed in its status line READY The LC2 line cards check for the presence of the telephone line periodically when in stand by mode The line card LED indicates the line test by a short yellow pulse The line test is based on true ...

Страница 28: ...yed for review and a Fault Data message will be sent to the CPM The type of faults can be the following BAD CRC CHECKSUM DATA ERROR REPEAT FAILED UNKOWN FORMAT Note that although the Line Card can automatically identify most of the formats some of the communication formats must be enabled selected by programming 2 way Audio Mode There are two methods of activating 2 way Audio mode The first is the...

Страница 29: ...ay 0000 CALL 2975125 2 15 40 02 0000 FAULT CALL 2 15 40 02 NOTE As usually and account always makes calls from the same telephone line the account ID and the calling number can be matched The assignment of the account code to the calling number by the line card makes possible to use advanced event checking options in the monitoring software on the PC E g filtering out invalid account calling numbe...

Страница 30: ...of the line card telephone hybrid so that it might detect ringing If the number of rings set to 1 in this case the line card might stuck in a continuous communication attempt and will not be able to receive calls Due to this issue It is highly recommended to set the number of rings to minimum 2 to avoid such problems as more and more Service Providers change existing analog PCM connections to VOIP...

Страница 31: ...values define an account group for 2 way audio The first two digits of the account code must be within the range defined by these values to allow 2 way audio for the given account Example 33 33 33xx accounts 18 2F 18xx 2Fxx accounts 00 00 no accounts allowed for 2 way audio The second two values define the event code range that will activate the 2 way audio for the line card For example 81 81 The ...

Страница 32: ...it the internal statistics of the line card are listed These values may help finding possible problems of the line card At the Line Card Status screen it is possible to reset the selected line card by pressing the RESET F3 button The line card will perform its power on test sequence and then starts up in standby mode 32 ...

Страница 33: ... 300 113 compatible UHF radio 440 450MHz frequency range 12 5kHz raster FM modulation 1 way VBRC radio protocols supported 2 way Enigma II radio protocol supported Full Contact ID reporting support Programmable reception parameters CPM2 supervision standalone operation in case of CPM2 failure 500 event internal memory buffer RC2 Operation The RC2 card performs similar to the LC2 cards on the Statu...

Страница 34: ...re Manual for details RC2 Radio Card Settings Several paramters of the RC2 Radio Card can be programmed by the user manually with the controls of the Enigma II receiver These settings can be accessed by pressing F2 SETUP at the menu of the RC2 card Doing that the following dialog appears Figure 20 Radio Card Settings The currently selected field is flashing Skip between fields with the Left and Ri...

Страница 35: ... RC2 card will receive communications from all subsystems without filtering SWR Display The bar graph display and noise band limit can be set here The first value is the minimum value to display the third is the maximum value to display The bar graph will be calibrated between these two values The second value is the noise band limit signal power above this limit will turn on the audio monitoring ...

Страница 36: ...ttery If the LED blinks fast it indicates a problem of the power supply Battery Testing The Power Card checks for battery presence regularly and conducts an active battery test every hour It also makes the active test after the battery is connected to the receiver The battery testing does not affect receiver operation in any way as the system supply and the battery charger are independent of each ...

Страница 37: ... offline or out of paper PRINTER OK 8E Printer is ready RECEIVER RESET 8F Receiver has been reset TIME DATE SET 91 Time and Date has been set PROGRAM ACCESS 92 Program access via the serial port PROGRAM END 93 Programming finished via the serial port REMOTE ACCESS 94 Remote programming access REMOTE END 95 Remote programming finished MANUAL ACK 96 Manual acknowledgement ACCESS GRANTED 97 Access to...

Страница 38: ...co Slow 1400 Hz 1900 Hz pulse 10 bps 3 1 3 2 4 1 4 2 1400 Hz Silent Knight Fast 1400 Hz 1900 Hz pulse 14 bps 3 1 3 2 4 1 4 2 1400 Hz Franklin Sescoa 2300 Hz 1800 Hz pulse 20 bps 3 1 3 2 4 1 4 2 2300 Hz Radionics 1400 Hz 1800 Hz pulse 40 bps 3 1 4 2 3 1 p 4 2 p 1400 Hz Radionics 2300 Hz 1800 Hz pulse 40 bps 3 1 4 2 3 1 p 4 2 p 2300 Hz Sescoa SuperSpeed 2300 Hz 1800 Hz pulse 40 bps 4 3 p 2300 Hz Con...

Страница 39: ...consult manual for supported formats Problem Telephone line fault Solution Check the telephone line connections for cut or short Problem Fault call on the Line Card Solution Check that the handshake needed for the control panel is programmed for the Line Card Check that the handshake is being sent properly Use Audio Monitoring option Check that the control panel answers the handshake modify handsh...