REPLACING
COMPONENTS
Combustion
Blower
Before
beginning
any
component
replacement,
be
certain
the
unit
is
unplugged
and
thoroughly
cooled
down.
Remove
the
left
side
panel
and
locate
the
combustion
(exhaust)
blower.
Disconnect
the
venting
system
from
the
exhaust
blower,
and
disconnect
the
exhaust
blower
from
the
stove
wiring
harness.
To
remove
the
venting
pipe,
removal
of
the
rear
panel
(using
a
5
/
16
”
wrench)
may
be
necessary.
Remove
all
(5)
screws
which
hold
the
exhaust
blower
to
the
exhaust
blower
tube.
Remove
the
heat
sensor
which
is
connected
(with
a
screw)
to
the
exhaust
blower.
Once
the
screws
have
been
removed,
the
blower
can
be
lifted
up
and
out
of
the
stove.
Reinstallation
is
the
exact
opposite
of
the
steps
above;
however,
be
certain
to
check
the
condition
of
the
exhaust
blower
gasket
and
replace
if
necessary.