11
IMPORTANT!
READ
AND
FOLLOW
ALL
INSTALLATION
AND
MAINTENANCE
INSTRUCTIONS,
INCLUDING
CLEANING
THE
UNIT
AS
SPECIFIED,
AND
REPLACING
GASKETS
ANNUALLY,
AND
PARTS
AS
NEEDED.
ENGLAND’S
STOVE
WORKS
IS
NOT
RESPONSIBLE
FOR
ANY
DAMAGE
OR
INJURY
INCURRED
DUE
TO
NEGLECT,
OR
DUE
TO
UNSAFE
INSTALLATION
OR
USAGE
OF
THIS
PRODUCT.
CALL
TECHNICAL
SUPPORT
WITH
ANY
QUESTIONS.
INSTALLATION
Approved
Venting
Method
1:
Through
the
Wall
Generally
the
simplest
installation
method,
venting
through
the
wall
using
our
AC
‐
3000
kit,
AC
‐
33000
if
Canada
(or
similar
venting
system)
is
also
the
preferred
venting
method.
It
minimizes
horizontal
pipe,
allows
the
stove
to
be
installed
close
to
the
wall
and
keeps
the
clean
‐
out
tee
on
the
outside
of
the
house,
for
ease
of
cleaning.
When
installing
any
venting
system,
Type
L
or
Type
PL
pipe
must
be
used
and
all
clearances
to
combustibles
(listed
by
the
pipe
manufacturer)
must
be
strictly
adhered
to.
Use
the
pipe
manufacturer’s
approved
thimble
for
passing
through
a
combustible
wall,
and
maintain
at
least
the
minimum
clearances
to
combustibles.
Use
an
appliance
collar
where
the
pellet
vent
connects
to
the
exhaust
output
of
the
pellet
stove
and
attach
the
appliance
collar
to
the
exhaust
blower
output
using
three
sheet
metal
screws.
Secure
the
pellet
vent
to
the
outside
of
the
house
using
a
wall
strap
just
below
the
90
degree
elbow.
Seal
each
pipe
connection
joint
with
high
temperature
RTV
Silicone,
to
ensure
the
system
is
leak
free
(Check
with
the
specific
venting
system
manufacturer’s
instructions
before
doing
so).
If
the
pellet
vent
pipe
being
used
is
not
a
“Twist
Lock”
system,
three
(3)
sheet
metal
screws
are
required
at
each
pipe
joint.
Connect
the
pellet
stove
to
outside
combustion
air
using
the
kit
included
with
your
stove
or
using
an
alternative
method,
as
described
in
the
“Outside
Air”
section,
on
page
16.
This
installation
type
can
be
modified
for
basement
(Basement
installations
should
always
be
performed
by
a
professional
installer)
or
other
installations
wherein
the
tee
and
vertical
section
of
the
pipe
would
be
inside
the
home
and
the
venting
system
would
simply
pass
horizontally
through
the
thimble
and
then
terminate.
Please
Note:
Installation
diagrams
are
for
reference
purposes
only
and
are
not
drawn
to
scale,
nor
meant
to
be
used
as
plans
for
each
individual
installation.
Please
follow
all
venting
system
requirements,
maintain
the
required
clearances
to
combustibles,
and
follow
all
local
codes.
For
high
altitude
installations
(above
4,000
ft.),
the
vent
pipe
should
be
increased
from
3
‐
inch
(3”)
to
four
‐
inch
(4”).