ENFORCER Delayed Egress Timer 

 

 

SECO-LARM U.S.A., Inc                                                                                      9

 

SECO-LARM U.S.A., Inc.                                                                                                   

               33                                              

9                                                                                         

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset Input (N.C.+): 

 

Connect a N.C. switch between the reset input and the positive terminal. 

 

The reset input is used to reset the SA-025EQ. 

 

The reset input is only necessary in the standard relock mode. 

Initiate Input (N.C.+): 

 

Connect a N.C. device (such as the SD-961A-36 Push-to-Exit Bar) between the initiate 

input and the positive terminal. 

 

The initiate input is used to activate the SA-025EQ. 

 

To activate, hold down the initiate input for the duration of the nuisance delay timer. 

Lock Status Input (N.C.+): 

 

Connect a N.C. magnetic contact (such as the SM-200Q) between the lock status input and 

the positive terminal. 

 

The lock status input will detect if the door on which the magnetic contact is mounted is 

closed in order to trigger the relock functions. 

 

Power Input (12~24 VAC/VDC): 

 

The SA-025EQ is powered by a 12~24 VAC or VDC power supply. 

 

LED 1 (blue) is on when the SA-025EQ is powered. 

 

Bypass Input (N.C.+): 

 

Connect a N.C. switch between the bypass input and the positive terminal. 

 

The bypass input is used to bypass the SA-025EQ and allow unrestricted entry and exit via 
the door. 

 

When the bypass input is activated, the lock will immediately release. It will remain released 

until the bypass input is deactivated. 

 

The bypass input will not trigger the remote alarm or local alarm. 

 

If not used then a jumper must be installed between the bypass input and the positive 
power input terminal. 

Free Egress Input (N.C.+): 

 

Connect a N.C. toggle switch between the free egress input and the positive terminal. 

 

The free egress input allows the lock to be put in the free egress mode. This bypasses any 

delays and alarms, allowing the initiate device to act as a simple egress device. 

 

In the free egress mode, the lock is released as soon as the initiate device is triggered. 

 

The door will relock after 5 seconds. 

 

This can be used in conjunction with a timer (such as the SA-027Q annual timer) to allow 
free egress during the day, but restricted access at night. 

 

The remote alarm will also signal during free egress if the door is left open longer than  
5 seconds (the lock status jumper must be ON for this to occur). 

 

If not used then a jumper must be installed between the free egress input and the positive 
power input terminal. 

 

 

Содержание ENFORCER SA-025EQ

Страница 1: ...lay outputs for lock relay and remote alarm Transistor ground output for local alarm outputs Auto or programmed relocking after power loss IMPORTANT Users and installers of this product are responsibl...

Страница 2: ...put Form C 10A 24VDC Local alarm output transistor ground 500mA 12VDC Door status input Status LEDs show relay status Bypass input immediately releases locks Free egress input allows easy egress durin...

Страница 3: ...er see pg 6 Post delay timer potentiometer see pg 6 Terminal block see pg 4 LED 1 Blue If ON the SA 025EQ is being powered see pg 9 LED 2 Red If ON the lock relay is energized see pg 8 LED 3 Red If ON...

Страница 4: ...holes located on the side of the unit to a mounting surface Normally energized Screen print refers to energized state as normal Remote alarm relay output 10A 24VDC Form C Relay NO NC COM see pg 8 Loc...

Страница 5: ...relocked by a reset device connected to the Reset Input For information on connecting a reset device see pg 4 Wiring Diagram This reset device is often a momentary spring loaded key switch BOCA Mode T...

Страница 6: ...h at the bottom right of the circuit board Power Up Mode DIP Switch 1 There are two types of power up modes These modes determine the relocking status in case of a power loss Programmed Relock DIP Swi...

Страница 7: ...al alarm pulses during the pre delay gradually pulsing faster until the end of the pre delay time The local alarm will continue signaling steady 5 seconds after the lock has been released When set OFF...

Страница 8: ...e pg 7 LED 4 red is on when the local alarm output is active Lock Relay Output The SA 025EQ is equipped with a 10A 24VDC Form C dry relay output that can be used with a fail safe or fail secure lock T...

Страница 9: ...e bypass input is used to bypass the SA 025EQ and allow unrestricted entry and exit via the door When the bypass input is activated the lock will immediately release It will remain released until the...

Страница 10: ...ted to the reset input This device will manually reset the lock 4 A spring loaded switch is connected to the pre delay bypass input This will allow any authorized user immediate access to the protecte...

Страница 11: ...mon terminal is connected to a positive voltage and the normally closed terminal is connected to the SA 025EQ s initiate input 3 An audible indicator sounds during the pre delay time to alert the user...

Страница 12: ...rkmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any speci...

Отзывы: