ENFORCER Delayed Egress Timer 

 

 

SECO-LARM U.S.A., Inc                                                                                      11

 

SECO-LARM U.S.A., Inc.                                                                                                   

               33                                              

11                                                                                         

 

 

Sample Application – Installation with a Gate Operator 

 

In this application, the SA-025EQ is used to warn that a gate is about to open or close. 

 

This application is only for gates that use the same input for both opening and closing the gate. 

 

Relock mode set to standard mode. 

 

Pre-delay timer set to 15 seconds. 

 

Power-up mode set to automatic relock (DIP Switch 1 OFF). 

 

Nuisance delay set to 0 seconds (DIP Switch 2 and 3 OFF). 

 

Lock status jumper OFF. 

 

Security mode jumper OFF. 

 

Local alarm output type jumper ON. 

1.

 

A wireless initiate device, such as the SK-919TD1S-UP, is triggered. 

2.

 

A wireless receiver, such as the SK-910RBQ receives the signal. The receiver’s common terminal 
is connected to a positive voltage and the normally closed terminal is connected to the SA-025EQ’s 
initiate input. 

3.

 

An audible indicator sounds during the pre-delay time to alert the user that the gate  
is about to open. The local alarm will remain active for 5 seconds after the gate starts opening. 

4.

 

A gate operator connected to the lock relay output is triggered and opens a gate. 

5.

 

A gate warning light, such as the SL-1301-BAQ LED Strobe Light, signals while the gate is 
opening. 

6.

 

The wireless receiver is also connected to the reset input. After the gate has opened, the  
SK-919TD1S-UP is triggered again, deactivating the SA-025EQ. 

7.

 

The bypass input and free egress input are not used. Jumpers are placed between the bypass 
input, free egress input, and positive power input terminal. 

Power 
supply 

Gate warning 

light 

Gate 

operator 

Audible warning 

indicator 

Wireless 

transmitter 

Wireless  

receiver 

Содержание ENFORCER SA-025EQ

Страница 1: ...lay outputs for lock relay and remote alarm Transistor ground output for local alarm outputs Auto or programmed relocking after power loss IMPORTANT Users and installers of this product are responsibl...

Страница 2: ...put Form C 10A 24VDC Local alarm output transistor ground 500mA 12VDC Door status input Status LEDs show relay status Bypass input immediately releases locks Free egress input allows easy egress durin...

Страница 3: ...er see pg 6 Post delay timer potentiometer see pg 6 Terminal block see pg 4 LED 1 Blue If ON the SA 025EQ is being powered see pg 9 LED 2 Red If ON the lock relay is energized see pg 8 LED 3 Red If ON...

Страница 4: ...holes located on the side of the unit to a mounting surface Normally energized Screen print refers to energized state as normal Remote alarm relay output 10A 24VDC Form C Relay NO NC COM see pg 8 Loc...

Страница 5: ...relocked by a reset device connected to the Reset Input For information on connecting a reset device see pg 4 Wiring Diagram This reset device is often a momentary spring loaded key switch BOCA Mode T...

Страница 6: ...h at the bottom right of the circuit board Power Up Mode DIP Switch 1 There are two types of power up modes These modes determine the relocking status in case of a power loss Programmed Relock DIP Swi...

Страница 7: ...al alarm pulses during the pre delay gradually pulsing faster until the end of the pre delay time The local alarm will continue signaling steady 5 seconds after the lock has been released When set OFF...

Страница 8: ...e pg 7 LED 4 red is on when the local alarm output is active Lock Relay Output The SA 025EQ is equipped with a 10A 24VDC Form C dry relay output that can be used with a fail safe or fail secure lock T...

Страница 9: ...e bypass input is used to bypass the SA 025EQ and allow unrestricted entry and exit via the door When the bypass input is activated the lock will immediately release It will remain released until the...

Страница 10: ...ted to the reset input This device will manually reset the lock 4 A spring loaded switch is connected to the pre delay bypass input This will allow any authorized user immediate access to the protecte...

Страница 11: ...mon terminal is connected to a positive voltage and the normally closed terminal is connected to the SA 025EQ s initiate input 3 An audible indicator sounds during the pre delay time to alert the user...

Страница 12: ...rkmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any speci...

Отзывы: