Wireless Video Door Phone
6
SECO-LARM U.S.A., Inc.
R
es
et
6
5
4
3
2
1
The camera is connected to its included AC adapter.
The egress input is connected to a Request-to-Exit Plate. The homeowner can exit the
premises by pressing this button.
The N.O. (normally open) output is wired to an electric lock. The camera and the
Request-to-Exit Plate both activate the strike, allowing entry or egress.
The electric lock's power supply is wired to the COM (common) output.
COM
N.C.
N.O.
Egress input (N.O., -)
(+)
(–)
PUSH
TO
EXIT
Request-to-exit plate
Electric strike
power supply
Fail-secure
electric strike
To the included AC adapter or
the doorbell's transformer
Negative (-) (black wire)
Positive (+) (red wire)
1
2
3
4
5
6
Camera
Camera Wiring Diagram
1.
Positive (+) power input – Connect to the red wire of the included AC adapter or to the positive
wire of the doorbell's power supply.
2.
Negative (-) power input – Connect to the black wire of the included AC adapter or to the
negative wire of the doorbell's power supply.
3.
Egress (N.O.) negative input – Connect to an optional N.O. egress device. The egress device
will activate the relay for the same length as the lock delay. (See
Unlocking Duration
in
Programming the Advanced Settings
, pg. 10).
4.
N.O. (Normally opened) output – Wire to the lock device for fail-secure operation.
5.
N.C. (Normally closed) output – Wire to the lock device for fail-safe operation.
6.
Common output – Wire to the power supply of the lock device.
NOTE:
For 16VAC doorbell installation, wire directly from the doorbell's transformer.
Sample Application
COM
N.C.
N.O.
Egress input (N.O., –)
(–)
(+)
9~16 VAC/
5~16 VDC
Relay