86
Euromax Pellet Stove Installation and Operation Manual
Instead, if the installation consisted of a horizontal vent coming out at
the back of the stove on a total distance of 4 feet, followed by a tee
and a 6-foot vertical rise, it would be acceptable. The termination is
within the allowable configuration zone on the chart since it would
have at least one foot of vertical rise for each foot of horizontal run.
Furthermore, the total vertical rise is at least 3-feet high.
WARNING: To reduce the risk of smoke spillage there should
always be at least one foot of vertical rise for each foot of
horizontal run. In all cases, at least 3 feet of vertical rise is
needed.
Содержание Euromax
Страница 63: ...Euromax Pellet Stove Installation and Operation Manual 63 10 Wiring Diagram ...
Страница 75: ...Euromax Pellet Stove Installation and Operation Manual 75 15 Exploded View and Replacement Parts SECTION A ...
Страница 76: ...76 Euromax Pellet Stove Installation and Operation Manual SECTION B ...
Страница 77: ...Euromax Pellet Stove Installation and Operation Manual 77 SECTION C ...
Страница 78: ...78 Euromax Pellet Stove Installation and Operation Manual SECTION D SECTION E ...
Страница 79: ...Euromax Pellet Stove Installation and Operation Manual 79 SECTION F SECTION G ...
Страница 80: ...80 Euromax Pellet Stove Installation and Operation Manual SECTION H SECTION I ...
Страница 81: ...Euromax Pellet Stove Installation and Operation Manual 81 SECTION J ...