DO NOT USE PLIERS OR OTHER TOOLS TO TIGHTEN THE WING NUTS. 

To clean the baffle, pivot the lock plate (A)  by 90°  found above the access door of the 
combustion chamber. The baffle (B) will rotate and drop the accumulated fly ash. Clean and 
reinstall the baffle.  

 

1)  To remove the baffle (for a replacement) pivot the lock plate (A) by 90°. When the baffle 

has ended its rotation, place the lock to its initial position. 

2)  Lift the baffle (B) above its pivots and lower it by gently pulling towards you. To take it out 

of the door, you must rotate it slowly towards you to avoid hitting the walls of the 
combustion chamber. 

  

 

Содержание Euromax

Страница 1: ... AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH READ AND KEEP THIS MANUAL FOR REFERENCE This manual is available for free download on the manufacturer s web site It is a copyrighted document Re sal...

Страница 2: ...ove as you build and maintain your pellet heating system We highly recommend that our pellet burning hearth products be installed and serviced by professionals who are certified in the United States by NFI National Fireplace Institute or in Canada by WETT Wood Energy Technology Transfer or in Quebec by APC Association des Professionnels du Chauffage Congratulations on making a wise purchase To rec...

Страница 3: ...4 5 2 Through Wall Installation Main Floor or Basement 18 4 5 3 Through Roof Installation 19 4 5 4 Through a Factory Built Chimney 20 4 5 5 Through an Existing Masonry Fireplace 21 4 5 6 Through an Existing Masonry Chimney 22 PART B OPERATION 23 5 General information 23 5 1 Operation Warnings Cautions and Recommendations 23 5 1 1 Zone Heating and How to Make It Work for You 25 5 2 Combustible 26 5...

Страница 4: ...nents 53 9 3 Main Error Codes Possible Causes and Solutions 53 9 3 1 Blocked Flue 54 9 3 2 No Fuel 55 9 3 3 Failed Ignition 57 9 3 4 Defective Igniter Fuse 58 9 3 5 Auger Fuse 58 9 3 6 Unit Overheat 59 9 3 7 Hopper Lid Open 60 9 3 8 Power Loss 61 9 3 9 Smoke Smell 61 9 3 10 Combustion Air Starvation 62 9 3 11 The LCD Touch Screen Does Not Lightup 62 10 Wiring Diagram 63 11 Access to Fuses 64 12 Co...

Страница 5: ... not only reduce dependence on finite supplies of fossil fuels like oil and gas but they also put to good use materials that would otherwise unnecessarily and expensively add to our waste disposal problems In addition pellet stoves burn very cleanly and offer the lowest emissions of unwanted pollutants of all solid fuel burning appliances 1 1 1 Top 10 Reasons for Buying a Pellet Stove Fuel is rela...

Страница 6: ... Burn rate 1 2 lb to 8 2 lb per hour Energy consumption 3 7A for ignition cycle 2 15A Min 2 9A Max for continuous operation Electrical requirements 120VAC 15A Control board fuses Main 7 5A 250V fast blow fuse Convection blower 5A 250V fast blow fuse Combustion blower 3A 250V fast blow fuse Exhaust blower 3A 250V fast blow fuse Auger motor 1 3A 250V fast blow fuse Auger motor 2 3A 250V fast blow fu...

Страница 7: ...Euromax Pellet Stove Installation and Operation Manual 7 1 3 Overall Exterior Dimensions A FRESH AIR INLET B EXHAUST ...

Страница 8: ...ONS BURNING ANY SOLID FUELS GENERATES CARBON MONOXIDE IN LOW CONCENTRATION THIS GAS IS EVACUATED BY THE VENTING SYSTEM IN HIGHER CONCENTRATIONS CARBON MONOXIDE IS TOXIC AND MAY CAUSE DEATH TO PREVENT THIS ENSURE THAT YOUR VENTING SYSTEM IS AIRTIGHT THIS STOVE IS MOBILE HOME APPROVED AND REQUIRES INSTALLATION OF A FRESH AIR KIT SOLD SEPARATELY THE STOVE MUST BE ATTACHED TO THE STRUCTURE OF THE MOBI...

Страница 9: ...PILLAGE THE VENTING SYSTEM SHOULD BE CHECKED AT LEAST TWICE A YEAR FOR ANY BUILDUP OF SOOT OR CREOSOTE NEVER BLOCK ANY LOUVERS OF THE STOVE IF REQUIRED A FRESH AIR KIT CAN BE INSTALLED TO SUPPLY COMBUSTION AIR TO THE ROOM OR SPACE SEE APPENDIX F COMBUSTION AIR SUPPLY MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING COMPONENTS IS PROHIBITED AND WILL VOID THE WARRANTY ANY MODIFICAT...

Страница 10: ...ust be connected to a pellet vent system complying with the requirements for Pellet Vent in the standards UL 103 UL 641 ULC S629M CAN ULC S609 and ULC ORD C441 or to a code approved masonry chimney with a stainless steel flue liner 2 3 Before Operating Your Stove Some minor installation and adjustment are required prior to use If desired LCD sliding support can be installed on the left at the back...

Страница 11: ... STOVE MAY BE LOCATED CLOSER TO COMBUSTIBLES THAN THE MINIMUM CLEARANCES SPECIFIED ON THE CERTIFICATION LABEL CAUTION NO PART OF THE PELLET VENT SYSTEM MAY BE LOCATED CLOSER TO COMBUSTIBLES THAN THE MINIMUM CLEARANCES SPECIFIED BY THE VENT MANUFACTURER CAUTION 3 1 Certification Label Location DO NOT USE MAKESHIFT MATERIALS OR MAKE ANY COMPROMISES WHEN INSTALLING THIS STOVE Since the information gi...

Страница 12: ...ish to install the stove with minimum clearances see table in Section 3 2 Minimum Clearances to Combustibles it is possible to locate the LCD touch screen elsewhere but within the maximum length of the Telco wire provided You could also want to install the LCD sliding support on the left side of the stove see Appendix B Repositioning the LCD Sliding Bracket 3 4 Corner Installation For a corner ins...

Страница 13: ...de floor protection for built in raised hearths Check local codes for approved alternatives THE STOVE MUST BE PLACED ON A CONTINUOUS GROUTED JOINTS NONCOMBUSTIBLE MATERIAL SUCH AS CERAMIC TILE CEMENT BOARD BRICK MILLBOARD OR EQUIVALENT OR ANY OTHER APPROVED OR LISTED MATERIAL SUITED FOR FLOOR PROTECTION 4 Venting system 4 1 General Even though the chimney draft is mechanical a suitable venting sys...

Страница 14: ...iner provided the chimney is more than 4 in diameter The liner should be listed and should meet the ULC S635 CAN ULC S640 standard in Canada and the UL 1777 standard in the USA Refer to the instructions provided by the vent manufacturer especially when passing through a wall ceiling or roof 4 3 Equivalent Vent Length EVL Recommended venting system inner pipe diameter is 4 To calculate the EVL of y...

Страница 15: ... foot of vertical rise for each foot of horizontal run Instead if the installation consisted of a horizontal vent coming out at the back of the stove on a total distance of 4 feet followed by a tee and a 6 foot vertical rise it would be acceptable The installation end should be within the allowable configuration zone on the chart since it would have at least one foot of vertical rise for each foot...

Страница 16: ...nce to window or door that may be opened F 39 100 cm Clearance to corner or adjacent wall H 39 100 cm Not to be installed above a meter regulator assembly within 39 100 cm horizontally from the vertical center line of the regulator and for 15 vertically I 72 183 cm Clearance to gas service regulator vent outlet or within 39 100 cm of an oil tank vent or an oil tank fill inlet J 39 100 cm Clearance...

Страница 17: ... restrictions may apply See NFPA 211 for further information 4 5 Installation Configurations 4 5 1 Installation Warnings Cautions and Recommendations Reminder PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED THIS STOVE USES A PRESSURIZED VENTING SYSTEM ALL VENT CONNECTOR JOINTS MUST BE SEALED AND FASTENED CONSULT THE PELLET VENT MANUFACTURER S INSTRUCTION TO ENSURE PROPER INSTALLATION CONSISTENT P...

Страница 18: ...to go through the wall thimble and extend at least 6 inches beyond the exterior wall 4 Attach cap and seal outside wall thimbles with high temperature waterproof silicone sealant CAUTION TO REDUCE THE RISK OF SMOKE SPILLAGE THERE SHOULD ALWAYS BE AT LEAST 12 30 CM OF VERTICAL RISE FOR EACH FOOT OF HORIZONTAL RUN IN ALL CASES AT LEAST 36 91 CM OF VERTICAL RISE IS NEEDED BEFORE THE TERMINATION WARNI...

Страница 19: ...let and mark location on the ceiling Install the ceiling support and the vent pipe by following the vent manufacturer s instructions 4 Always follow vent manufacturer s clearances instructions from combustible materials When passing through additional floors or ceilings always install a fire stop spacer 5 After lining up for hole in roof cut either a round or square hole in roof Install upper edge...

Страница 20: ... the exhaust and the tee If you wish to center the vertical part of the vent with the stove a 45 elbow and a tee can be used to route the pipe from the exhaust towards the back center of the stove 3 Connect the pellet vent to the stainless steel liner according to the vent manufacturer s instructions 4 Seal and install vertical roof vent If required seal and install a storm collar WARNING IN THE U...

Страница 21: ... out tee is centered in the chimney flue area 4 Install a vented flashing at the top of the fireplace chimney Stainless steel plate and screws are recommended Cut a hole for the vent pipe If needed cut a second hole for the air intake pipe Seal all joints with high temperature waterproof silicone sealant to prevent water leakage 5 Seal and install vertical roof vent If required seal and install a ...

Страница 22: ...for the air intake pipe Seal all joints with high temperature waterproof silicone sealant to prevent water leakage 5 Install the cleanout tee at the bottom of the vertical vent system and lower it down the chimney until the center branch of the tee is aligned with the hole in the masonry 6 Install and seal flashing with high temperature waterproof silicone sealant 7 Seal and install vertical roof ...

Страница 23: ...ON IT IS HIGHLY RECOMMENDED THAT THE USER BUYS THIS PRODUCT FROM A RETAILER WHO CAN PROVIDE INSTALLATION AND MAINTENANCE ADVICE THIS STOVE MUST SERVE AS A SUPPLEMENTARY HEAT SOURCE AN ALTERNATIVE HEAT SOURCE SHOULD BE AVAILABLE IN THE HOME IF NEEDED THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR ADDITIONAL HEATING COSTS ASSOCIATED WITH THE USE OF AN ALTERNATIVE HEAT SOURCE USING A STOVE WITH CRAC...

Страница 24: ... SOIL OR OTHERWISE LOCALLY DISPERSED THEY SHOULD BE RETAINED IN THE CLOSED CONTAINER UNTIL ALL ASHES HAVE BEEN THOROUGHLY COOLED DO NOT OPERATE THE STOVE IF YOU SMELL OR SEE SMOKE TURN IT OFF MONITOR IT AND CALL YOUR DEALER IF NECESSARY DO NOT UNPLUG IT NEVER OPEN THE DOOR IT IS RECOMMENDED TO UNPLUG THE STOVE WHEN IT S NOT IN USE FOR PROLONGED AMOUNT OF TIME I E DURING SUMMER SENSORS ON THE STOVE...

Страница 25: ... NOT UNPLUG IT DO NOT OPEN THE DOOR OR THE HOPPER LID MAKE SURE THAT THE FRESH AIR INTAKE SHUTTER WORKS FREELY WAIT UNTIL SMOKE INSIDE THE FIREBOX CLEARS AND BLOWERS SHUT DOWN DO AS INSTRUCTED IN EVERYDAY STARTUP THEN ATTEMPT TO RESTART THE STOVE IF THE PROBLEM PERSISTS CONTACT YOUR DEALER NOTE THAT SMOKE BUILD UP DURING IGNITION MAY OCCUR SMOKE CAN ACCUMULATE IN THE FIREBOX FOR A FEW SECONDS JUST...

Страница 26: ... burn differently The amount of ashes produced can also vary greatly Conventional pellets are those or 5 16 in diameter and not over 1 long Longer or thicker pellets will prevent proper pellet feed For example if the pellets are very short they will have more ease to accumulate and pile into the feed screws Thus the volume of pellets will be denser which will lead to an increase in BTU By contrast...

Страница 27: ...ed on the right hand side of the stove when facing it See Appendix B LCD Sliding Bracket for right hand side installation 6 1 1 LCD Touch Screen Controls Operation and Configuration The LCD control is an electronic visual display as well as a touch screen that will light up as you touch any location on the display area The main status page will then display different icons layout depending if the ...

Страница 28: ...erating mode Thermostat or manual Thermostatic mode calling for heat Settings button On Off button Feed screw button Burn rate parameters Burn rate adjustment Convection blower speed adjustment Feed screw parameters Feed screw button when on Button to stop the feed screw STOP FEED AND START PURGE SCREW ...

Страница 29: ...ose the settings icon Select SETUP You can choose between three languages English French or Spanish and between o F or o C Select o F or o C icon to display temperatures in the desired unit 6 1 4 Viewing Statistics From the main status page choose the settings icon Select TROUBLESHOOT and then using the arrows go to page 2 Statistics will be available between page 1 to 3 These statistics can be ve...

Страница 30: ...type of pellets being used Even though your stove can burn a large variety of wood pellets we strongly recommend the use of high quality pellets to obtain maximum performance out of your stove see Section 5 2 1 Proper Fuel When using lower quality combustible a restrictive venting system or using the stove in high altitude you may need to adjust the PILOT SETTING ADJUSTMENT and the FUEL QUALITY AD...

Страница 31: ...ngs by 5 for auger motor 1 and 10 for combustion and exhaust fan but will only apply during pilot cycle To restore default setting select DEFAULT 6 1 6 2 COMBUSTION ADJUSTMENT Fuel Quality Adjustment The COMBUSTION ADJUSTMENT will allow you to modify default settings by 5 for auger motor 1 and 10 for combustion and exhaust fan To restore default setting select DEFAULT Here are some situations wher...

Страница 32: ...rease the exhaust fan speed if vent configuration is too restrictive or flame height tends to be high at any combustion level see Appendix C Flame Characteristics 6 1 7 Convection Fan Speed Adjustment You can adjust the stove s convection fan speed for each combustion level selected Thus an adjustment range is offered to reduce or increase air distribution in the room Take note that not all fan ra...

Страница 33: ... turned OFF or if the stove runs out of pellets Indicates that the stove is in thermostat mode The red waves indicate that the thermostat is calling for heat It will heat at the selected combustion level until the thermostat has reached room temperature setting The waves will disappear once the thermostat has reached room temperature setting At this time the combustion level will switch into the s...

Страница 34: ...pilot cycle is selected the stove will shut down when the temperature set on the thermostat is reached Every time the thermostat will call for heat the stove will go through the complete ignition cycle 6 1 9 2 30 Minutes or 60 Minutes The pilot cycle begins when temperature set on the thermostat is reached It will last 30 or 60 minutes depending of the selected pilot cycle If the thermostat does n...

Страница 35: ...page Feed screw button Feed screw parameters Feed screw button when on Button to stop the feed screw 6 1 10 1 Feed and Start Use this option when you start the stove for the first time of the season or after the hopper ran out of pellets The auger will turn then the stove will automatically start an ignition cycle 6 1 10 2 Purge Screw Use this option to empty the auger at the end of the season Whe...

Страница 36: ... has been developed primarily to enable sales people to show the stove s functionalities in showrooms without starting it Thus when the DEMO mode is activated the stove will not turn on but all the components will operate as if the stove was on To disable the DEMO mode you must press the word DEMO MODE followed by OFF ...

Страница 37: ... from green to yellow during the igniting mode 7 3 Running Out of Pellets If your stove runs out of pellets the fire will slowly go out the convection fan will run until the heat sensor on the exhaust fan reads 115 F The cooling cycle will take a few minutes before all other motors stops When this temperature is reached a warning message NO FUEL will be displayed on the LCD screen To restart the s...

Страница 38: ...ustion air or a lack of maintenance If this happens your stove will become very hot If the stove becomes too hot UNIT OVERHEAT code will appear on the LCD screen Before starting the stove again make sure the recommended maintenance has been done properly Press the RESET button and then press the ON OFF icon on the Main Status Page If a UNIT OVERHEAT code occurs twice call you dealer He will be abl...

Страница 39: ...t will increase cleaning frequency See Section 5 2 1 Proper Fuel for recommended combustibles WARNING FAILURE TO CLEAN AND MAINTAIN THIS STOVE AS INDICATED CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS WARNING NEVER CLEAN WHEN HOT WARNING THE USE OF A DOMESTIC CENTRAL OR COMMERCIAL VACUUM CLEANER TO PERFORM THE MAINTENANCE OF YOUR PELLET STOVE IS NOT RECOMMENDED ASH PARTICLES MAY DAMAGE THE MO...

Страница 40: ...xchangers Take care in not damaging the sealing gasket when putting the panel aside Take the brush that was supplied with the stove and insert it into each tube in a complete motion from top to bottom IT IS IMPERATIVE TO SLIDE THE BRUSH COMPLETY DOWN IT WILL BE VERY DIFFICULT TO REMOVE THE BRUSH IF IT IS STOPPED HALFWAY IN ONE OF THE TUBES It is recommended to use an ash vacuum to remove dust esca...

Страница 41: ...fle B will rotate and drop the accumulated fly ash Clean and reinstall the baffle 1 To remove the baffle for a replacement pivot the lock plate A by 90 When the baffle has ended its rotation place the lock to its initial position 2 Lift the baffle B above its pivots and lower it by gently pulling towards you To take it out of the door you must rotate it slowly towards you to avoid hitting the wall...

Страница 42: ...haust Channel and Exhaust Blower Maintenance Exhaust channels and the exhaust blower are located on the left hand side of the stove The following procedure demonstrates how to perform inspection and cleaning In order to access the exhaust channels open the left side decorative panels Using a Philips or Robertson screwdriver remove both clean out traps by unlocking them Push the screw and give it a...

Страница 43: ...cate both openings Using the provided scraper remove the dirt in the bottom channel of the heat exchangers Use an ash vacuum to complete the cleaning operation Make sure that the gaskets are still in good condition replace them if needed 3 16 black round gasket ...

Страница 44: ...by combustion residues ashes or clinkers 1 Clean the burn pot using the scraper provided with the stove or a smaller one 2 The burn pot simply sits onto the air intake channel You must lift to remove it from the stove Two small pins guide the burn pot in place Make sure that the burn pot is well in place before turning on the stove as shown in the diagram ...

Страница 45: ...omax Pellet Stove Installation and Operation Manual 45 3 If necessary clean the air intake channel To reach the air intake channel clean out trap open the ash drawer access door and remove the ash drawer A ...

Страница 46: ...lation and Operation Manual 4 Unscrew the wing nut D to open the clean out trap E Vacuum the combustion residues 5 Verify that the clean out trap gasket is still in good condition replace it if needed 3 16 black round gasket AC06815 ...

Страница 47: ...sh drawer A of its contents open the ash pan access door by lifting the latch on the right hand side 2 Vacuum around the ash drawer and at the bottom of the combustion chamber WARNING ASH PAN MUST BE IN PLACE AND THE ASH PAN ACCESS DOOR MUST BE KEPT CLOSED AT ALL TIMES WHEN THE STOVE IS IN USE ...

Страница 48: ...PART WARNING DO NOT CLEAN THE GLASS WHILE IT S HOT WARNING DO NOT FORCE STRIKE OR ADOPT ANY BEHAVIOUR THAT COULD WEAKEN THE GLASS DOOR WARNING DO NOT OPERATE THE STOVE WITH THE GLASS REMOVED CRACKED OR BROKEN 8 1 8 Replacement of Broken Door Glass Carefully remove any loose pieces of glass from the doorframe Dispose of all broken glass properly A broken glass must be replaced with an identical ROB...

Страница 49: ...ted periodically making sure to obtain an air tight fit Air tightness can be improved with a simple latch mechanism adjustment To adjust 1 Remove the lock pin by pulling and turning with pliers Turn the handle counter clock wise one turn to increase pressure 2 Re install the lock pin spring pin with a small hammer 8 2 Venting System Maintenance CAUTION REGULARLY EXAMINE THE VENTING SYSTEM THE JOIN...

Страница 50: ...ow of combustion gases Incomplete combustion produced when igniting shut down or misuse of the stove will cause some soot formation which can accumulate in venting system The venting system must be inspected at least twice a year to determine if cleaning is necessary 9 Troubleshooting When you have issues with your stove your first reaction may be to call technical support This section will help y...

Страница 51: ...ity heat sensor o L 250A security heat sensor o Pressure switch security sensor o Hopper switch mechanical security sensor o Thermostat temperature regulator device Electrical components high power rated o Igniter heater o Combustion blower will feed fire with fresh air o Convection blower will send hot air into the room o Exhaust blower will extract combustion gas out of the stove o Auger motor 1...

Страница 52: ...de has occurred From page 4 is the list of operating states of the electronic components If the square is green it means that the operating state of the component is normal no matter if it s on the left column or right If the square is red it means that the operating condition is abnormal This screen will give you the operating status in real time meaning that when the stove is running if a state ...

Страница 53: ...IPULATE OR REPLACE ANY COMPONENTS THE STOVE NEEDS TO BE DISCONNECTED FROM THE WALL OUTLET This section contains main error codes possible causes and many suggestions to guide you in resolving them After giving an error code your stove will shut down by itself and start a cool down cycle If you want to start your stove again you will need to press on the button and then on the ON OFF button Your st...

Страница 54: ...rmination o The pressure switch wire connections are faulty Make sure that the pressure switch wires and connections are not grounded or loose Replace or replug wires if necessary o The pressure switch hose is disconnected Make sure the pressure switch hose is well installed on the exhaust blower pressure tap and on the white pressure switch tap If not reinstall it o The exhaust or combustion blow...

Страница 55: ...g Auger Housing v The burn pot holes are blocked Remove the burn pot and clean it thoroughly v The auger is jammed or auger motor failed Go to the troubleshooting page on the LCD see Section 9 2 Testing Components screen and test auger motors If one of the motors is not running check if motor is defective or if the auger is jammed HOPPER AUGER A Screws B Auger and motor assembly C gasket ...

Страница 56: ...or broken welds Remove any foreign material that may have caused the jam Inspect the auger housing for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam Clean the auger housing thoroughly to remove all pellet dust o If no object appears to block the auger reconnect the electrical connections of the motor and turn on the stove BE CAREFUL NOT TO TAK...

Страница 57: ...nected and the fuse is good disconnect the igniter and check its resistance ohms Ω with a multimeter If the value is near zero replace the igniter v The flue temperature sensor failed The thermistor is a heat sensor located on the exhaust motor housing Its function is to tell the control board that the stove has ignited properly by measuring the heat at the exhaust When the stove is cold check pag...

Страница 58: ...ger motor failed Go to the troubleshooting page see Section 9 2 Testing components on the LCD screen and test auger motors If one of the motors is not running check if motor is defective or jammed NOTE IF THE HOPPER AUGER MOTOR FAILED OR THE HOPPER AUGER IS JAMMED TO AVOID PELLET SPILLAGE EMPTY THE HOPPER OF ITS CONTENTS BEFORE EXECUTING THE FOLLOWING TESTS o If the auger motor is defective check ...

Страница 59: ...und the igniter Refer to the maintenance section Also make sure that the recommended fuel is used see Section 5 2 1 Proper Fuel v The flue is not properly installed Make sure the venting system meets the criteria in the Section 4 Venting System as well as the venting system manufacturer s instructions v The flue is blocked or needs cleaning One of the following components is obstructed or blocked ...

Страница 60: ...nents mentioned above ONCE THE MAINTENANCE DONE FOLLOW THESE INSTRUCTIONS After 3 attempts press restart and then enter the following code 999333555 and press accept The system will reset 9 3 7 Hopper Lid Open v The hopper lid remained open for more than 3 minutes As a security measure the auger stops turning and feeding pellets as soon as the hopper lid opens It will resume normal operation as so...

Страница 61: ...original parts if necessary Make sure the door is well adjusted see Section 8 1 9 Door Adjustment v Negative pressure A faint wood burning odor during ignition or shut down is normal Although if this increases beyond what is considered normal or if you notice an unusual soot build up on walls or furniture check your venting system carefully for leaks and make sure all gaskets are in good condition...

Страница 62: ...t blowers independently see Section 9 2 Testing Components If one of them does not function make sure there is power and that the blowers are properly connected If they still don t work check fuse F4 and F5 on the control board A blown fuse will be darkened or will have a broken filament If the fuses are in good condition the combustion or exhaust blower is probably defective Replace the faulty pa...

Страница 63: ...Euromax Pellet Stove Installation and Operation Manual 63 10 Wiring Diagram ...

Страница 64: ...1 Access to Fuses WARNING UNPLUG THE STOVE BEFORE CHANGING THE FUSES All fuses are located inside the housing of the electronic board the housing is on the back of your stove Unplug your stove remove the screw and turn the four spring clips to open the housing ...

Страница 65: ...et Stove Installation and Operation Manual 65 LETTER FUSE FUNCTION AMPERAGE A MAIN BOARD FUSE 7 5A B CONVECTION BLOWER 5A C COMBUSTION BLOWER 3A D EXHAUST BLOWER 3A E TOP AUGER 1 3A F BOTTOM AUGER 2 3A G IGNITOR 5A ...

Страница 66: ...BURN POT C IGNITOR D CONVECTION BLOWER E THERMISTOR F L 250 THERMAL SWITCH G HOPPER H TOUCH SCREEN CONTROL PANEL I HOPPER SAFETY SWITCH J PRESSURE SWITCH K F 160 THERMAL SWITCH L POWER CORD RECEPTACLE M THERMOSTAT TERMINAL BLOCK N COMBUSTION BLOWER FRESH AIR INTAKE O EXHAUST BLOWER P BOTTOM AUGER 2 Q TOP AUGER 1 R PC BOARD ...

Страница 67: ...7 13 Blower Replacement CONVECTION BLOWER Before disconnecting the wire harness from the convection fan assembly take note of which wire goes where Unscrew screw A with a screwdriver 1 Pull downwards on the convection fan and slide out for complete removal 2 ...

Страница 68: ...on Manual COMBUSTION BLOWER Remove the 9 screws A and the bottom grille B Unlatch the clamps C Remove the backdraft shutter G and the gasket D Pull the combustion blower F and unplug the wire connector from the harness Remove the plug E of the blower ...

Страница 69: ...Euromax Pellet Stove Installation and Operation Manual 69 EXHAUST BLOWER Remove the left panel Unplug the connections A and B Unplug the silicone tube C ...

Страница 70: ...70 Euromax Pellet Stove Installation and Operation Manual Remove the clamp D With a Philips screwdriver unlock and remove the access panel E ...

Страница 71: ...Euromax Pellet Stove Installation and Operation Manual 71 Remove the nuts F located in the opening of the trapdoor Remove the duct assembly G ...

Страница 72: ...72 Euromax Pellet Stove Installation and Operation Manual Remove the bolts H and nuts I to remove the exhaust blower J ...

Страница 73: ...eration Manual 73 14 L 250 and F 160 Thermal Switch Replacement L 250 1 Remove both retaining screws A holding the thermal switch support bracket B 2 Lift up the support bracket Rotate the bracket 90 clockwise then pull the bracket toward you ...

Страница 74: ... Stove Installation and Operation Manual Remove the faulty thermal switch Replace new thermal switch D underneath the bracket B by means of 2 screws C F 160 Unscrew both screws B and take out the thermal switch F 160 A ...

Страница 75: ...Euromax Pellet Stove Installation and Operation Manual 75 15 Exploded View and Replacement Parts SECTION A ...

Страница 76: ...76 Euromax Pellet Stove Installation and Operation Manual SECTION B ...

Страница 77: ...Euromax Pellet Stove Installation and Operation Manual 77 SECTION C ...

Страница 78: ...78 Euromax Pellet Stove Installation and Operation Manual SECTION D SECTION E ...

Страница 79: ...Euromax Pellet Stove Installation and Operation Manual 79 SECTION F SECTION G ...

Страница 80: ...80 Euromax Pellet Stove Installation and Operation Manual SECTION H SECTION I ...

Страница 81: ...Euromax Pellet Stove Installation and Operation Manual 81 SECTION J ...

Страница 82: ...E ACCESS PANEL 1 14 AC06900 BLACK 1 2 ROUND X 9 GASKET KIT WITH ADHESIVE 2 15 AC01220 BLACK CAST IRON DOOR OVERLAY 1 15 AC01222 BRUSHED NICKEL CAST IRON DOOR OVERLAY 1 16 30123 SCREW 8 32 X 5 8 PAN QUADREX ZINC 4 17 SE24179 01 DOOR ASSEMBLY WITH HANDLE AND GASKET 1 18 AC09153 HANDLE AND LATCH REPLACEMENT KIT 1 19 AC09185 DOOR LATCH KIT 1 20 30569 ROUND WOODEN HANDLE BLACK 1 21 AC06810 SELF ADHESIV...

Страница 83: ...20 X 3 4 HEX GRADE 5 3 55 SE44144 EXHAUST BLOWER ASSEMBLY 1 56 21392 EXHAUST ADAPTER GASKET 1 57 30762 VENT ADAPTER SECURE CLAMP 1 58 SE67018 EXHAUST ADAPTER PIPE 1 59 24030 AUGER 1 60 30092 BOLT 5 16 18 X 3 4 HEX GRADE 5 4 61 21193 AUGER SUPPORT GASKET 2 62 PL62281 AUGER BUSHING PLATE 1 63 30026 THREAD CUTTING SCREW 10 24 F 5 8 HEX WASHER HEAD 4 64 44106 GEAR MOTOR FOR PELLET STOVE AUGER 1 5 RPM ...

Страница 84: ...LD TO ORDER 1 94 30080 METAL SCREW 6 X 1 4 TYPE B PAN PHILLIPS 4 95 44058 THERMODISC 36T12 F160 1 96 PL62343 F 160 SUPPORT 4 97 PL67149 L250 25 AUTOMATIC SUPPORT 1 98 44059 THERMODISC 36T11 L250 25 AUTOMATIC 1 99 30439 SPING CLAMP 2 100 21391 COMBUSTION BLOWER GASKET 1 101 PL64359 COMBUSTION FAN GASKET FRAME 1 102 SE44147 AXIAL BLOWER ASSEMBLY 115V 9W 92 X 92 X 38 1 103 21400 COMBUSTION FAN GASKET...

Страница 85: ...sisting of a horizontal vent coming out at the back of the stove on a total distance of 8 feet This horizontal run is followed by a tee and a 6 foot vertical rise This type of installation is not acceptable As you can see the vent termination is clearly outside the allowed configuration zone on the chart because the venting system proposed does not have at least one foot of vertical rise for each ...

Страница 86: ...t would be acceptable The termination is within the allowable configuration zone on the chart since it would have at least one foot of vertical rise for each foot of horizontal run Furthermore the total vertical rise is at least 3 feet high WARNING To reduce the risk of smoke spillage there should always be at least one foot of vertical rise for each foot of horizontal run In all cases at least 3 ...

Страница 87: ...f the hot air distribution kit is to be installed see position 2 Step 1 To reverse the assembly to a left side configuration extend the rail with the LCD support A in order to gain access to the two screws B Remove the screws rotate the rail 180 and reassemble the rail to the mounting bracket C using the screws previously removed Step 2 Remove the screws D located on the top edge of the back of th...

Страница 88: ...lation and Operation Manual Step 3 Take the Telco black wire E which is located on the rear bottom panel and plug it into the back of the LCD touch screen interface receptacle Then secure the LCD touch screen housing F on the rail A ...

Страница 89: ... heat transfer to the heat exchanger therefore reducing convection efficiency Depending on the quality of the pellets there are usually more embers or sparks exiting the flame and burn pot To rectify this condition reduce combustion air flow to obtain a flame pattern as in image 1 Fire with not enough air If the flame pattern is tall lazy and orange with black smoky tips as in image 3 it is genera...

Страница 90: ...e thermostat is very important to obtain comfort and efficiency from your stove Locate the thermostat 4 to 5 feet above thefloor in accordance with applicable building codes Install the thermostat in a location that provides good air flow characteristics and avoid areas behind doors near corners air vents direct sunlight or heat generating devices If the thermostat is installed in the same room as t...

Страница 91: ...ar on the right hand side of the stove when facing it Loosen the two middle screws and insert the wires in the terminals Tighten the two screws Open the thermostat and connect the wires as per the manufacturer s instructions Here is an example of what your thermostat could look like Connect one wire on RH and the other wire on W Red wire jumper can remain installed For further information refer to...

Страница 92: ...at wires to the terminal block located at the rear on the right hand side of the stove while facing it If the receiver wires are equipped with quick connect terminals you can connect them directly to the stove s wiring harness To do so open the right hand side decorative panels and disconnect wires B and C attached to the rear of the terminal block A and connect them to the receiver ...

Страница 93: ...holes A located for this purpose on each side of the pedestal as shown on the following image For use in a mobile home in Canada this pellet stove must be connected to a vent system certified according to the standard or ULC ORD C441 CAN ULC S609 A vent system meeting the requirements of ULC S629M can also be used For use in a manufactured home in the United States this pellet stove must be connec...

Страница 94: ...tove Installation and Operation Manual A Fresh air intake B Tee C Pellet pipe length and or slip section D Ceiling support E Attic insulation shield F Roof flashing G Storm collar H Pellet pipe length I Vertical rain cap ...

Страница 95: ...D NEVER EXCEED 10 FEET It is recommended to install an outside air inlet in or near the room where the stove is installed When doing so it is preferable to choose a wall which is not exposed to dominant winds depending on the conditions surrounding your house An insulated 3 inside diameter metallic pipe either flexible or rigid must be attached to the fresh air intake D AIR SUPPLY INSULATED PIPE E...

Страница 96: ...nsulation and plastic cover exposing the flexible pipe Attach the flexible pipe using pipe clamps C For a better seal you may also use aluminum tape Wrap the tape around the joint between the flexible pipe and the air inlets Carefully push the insulation and plastic cover back over the pipe Fix the plastic in place using aluminum tape A rodent guard minimum 1 4 wire mesh must be used at the termin...

Страница 97: ...ces of Outside Combustion Air WARNING IT IS FORBIDDEN TO DRAW COMBUSTION AIR FROM A BASEMENT AN ATTIC A GARAGE OR ANY CONFINED SPACE You can draw air from a ventilated crawl space underneath the floor You can draw air directly from an outside wall behind the stove ...

Страница 98: ...er to complete the assembly of your Enerzone Euromax you need to install the door overlay A See figure below for installation instructions 1 Position the overlay A on the door frame and secure it in place from behind using the 4 screws B Note It is not necessary to remove the glass to install the overlay ...

Страница 99: ...eration Manual 99 APPENDIX H OPTIONAL HOT AIR DISTRIBUTION KIT AC01343 The hot air distribution kit for Enerzone Euromax will be available soon Call your local dealer for more detail This is an example only Hot air distribution kit may differ ...

Страница 100: ...ent part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective ...

Отзывы: