5
H
Solar water tank temp.
℃
0~125(C7)
℃
Error code P6
I
Exhaust temp.
℃
0~125(C7)
℃
Error code P7
III. Maintenance and Trouble Shootings
1. Maintenance
l
External cleaning: To clean the heat pump unit, the power must be cut off, and a small amount
of neutral detergent dipped in a wet cloth shall be used to gently wipe. Do not use gasoline or
acid solution, alcohol, and finally dry with a dry cloth.
l
Waterway cleaning: Empty and clean once every 3 months. Descaling materials: clean with
organic acids such as formic acid, citric acid, acetic acid, etc.
l
Evaporator cleaning:A hard nylon brush can be used to clean the fins of the evaporator.A
vacuum cleaner must be used Before cleaning. If there is compressed air, a high-pressure air
tube can be used to clean the fins of the heat exchanger.
l
Note: If the solar coil is optional, if the ambient temperature is lower than 2
℃
, anti-freeze
valves and pipelines shall be installed in the solar coil water channel and filled with anti-freeze
liquid, such as glycerin-aqueous solution or ethylene glycol aqueous solution.
l
Note: If the ambient temperature is lower than 2
℃
, please install circulating water pump on the
customer's water side to avoid freezing of pipeline during use. When the machine is out of
order, the water of the machine and the water side pipeline should be drained in time to avoid
freezing of the pipeline.The installation of water pump is shown in “Installation”.
Reference table of target concentration and target freezing point of unit antifreeze.
Glycerol
Local lowest ambient temp. (
℃
)
Antifreeze mass target concentration percentage (kg/kg %)
Antifreeze target
antifreeze point (
℃
)
0
<
T≤2
15
-3.2
-2
<
T≤0
20
-4.8
-4
<
T≤-2
25
-7.15
-6
<
T≤-4
30
-9.5
-8
<
T≤-6
35
-12.45
-12
<
T≤-8
40
-15.4
-17
<
T≤-12
45
-21.7
-25
<
T≤-17
50
-28
-29
<
T≤-25
55
-31.35
-31
<
T≤-29
60
-34.7
Glycol
Local lowest ambient temp. (
℃
) Antifreeze mass target concentration percentage (kg/kg %)
Antifreeze target
antifreeze point (
℃
)
Содержание BC-F20HWR2-200L
Страница 1: ...DOMESTIC INTEGRATED HEAT PUMP WATER HEATER Installation Instruction Manual MODELS BC F20HWR2 200L ...
Страница 2: ......
Страница 19: ...16 2 Account ID Password Login Existing accounts can be logged in directly in the following order ...
Страница 23: ...20 Step 5 When Scan devices Register on Cloud Initialize the device are all completed connect succeeds ...
Страница 29: ...26 l Mode settings Click on the main interface to switch modes select what you need ...
Страница 32: ...29 ...
Страница 33: ...30 ...