16
1
5
7
3
6
8
9
10
11
13
2
4
12
14
12
Figure 11, Fixed Blade Replacement
Key:
1. Clevis Pin
2. Clevis Pin
3. Retaining Ring
4. Retaining Ring
5. Screw (Qty. 5)
6. Lock Nut (Qty. 2)
7. Front Lifting Eye
8. Left Side Outer Plate
9. Fixed Blade
10. Inner Plate
11. Right Side Outer Plate
12. Socket Head Screw M18 x 70 (Qty. 2)
13. Socket Head Screw M18 x 96 (Qty. 2)
14. Socket Head Screw M18 x 90 (Qty. 8)
9.5.2 Moving Blade Replacement
Replace the moving blade as described in the following
steps:
1. Start the pump. Retract the piston to the home
position.
2. Stop the pump. Be sure that hydraulic pressure is
completely relieved.
3. Disconnect pump from AC power supply.
NOTICE:
WARNING
Always disconnect pump from AC
power supply before beginning cutter blade
replacement procedures. Failure to observe this
precaution could result in accidental startup as
procedures are being performed. Serious personal
injury could result.
4. Open the cutting head. Refer to Section 7.2 for
additional information.
5. Loosen and remove the moving blade screw
(Figure 12, item 1).