background image

Oil Heat – Eighteenth Edition – June 2015 

 

33

 

 

LIMITED LIFETIME WARRANTY 

For Residential Water Boilers 

 

By this Warranty Statement, Energy Kinetics, Inc of Clinton Township, New Jersey, issues limited warranties subject 

to terms, conditions, exceptions and exclusions listed below. 

These Warranties are issued only to the person or entity which owns the building in which the boiler is installed at the 

time of original installation and only for such portion of the warranty periods as such person or entity owns such building 
(hereinafter, the “End User”). 

I. 

THREE YEAR –LIMITED WARRANTY FOR RESIDENTIAL WATER BOILERS

 

Energy Kinetics warrants that its residential heating System 2000, with residential water boiler, Models EK1 and 

EK2, is free from defects in material and workmanship for three years from the date of installation.  If any parts are 
found to be defective in manufacture, Energy Kinetics will repair or replace the defective parts.  Exception: Honeywell 
Zone Valves 

 

II. ADDITIONAL COMPONENT LIMITED WARRANTIES 

1.  Energy Kinetics warrants that its Digital Energy Manager is free from defects in material and workmanship for a 

period of five years from the date of installation.  The warranty is extended to the End User for the lifetime of the 
unit by a manufacturer sponsored rebuild program offered at nominal cost. 

2.  Energy Kinetics hereby assigns to the End User limited warranties of the original manufacture of components 

supplied by Energy Kinetics to the extent or duration assignable. 

3.  If any such component is found defective, Energy Kinetics’ responsibility is solely to repair or replace the defective 

part at it’s or the original manufacturer’s option. 

 

LIMITED LIFETIME WARRANTY FOR THE PRESSURE VESSEL 

During the lifetime of the original owner in the original place of installation, Energy Kinetics warrants that those parts, 
which comprise the pressure vessel of the residential hot water boiler, remain free of defects in material or 
workmanship under normal usage. 

In the event that such pressure vessel is found to be defective in material or workmanship during the first ten 

years, Energy Kinetics will repair or replace the pressure vessel at its option and include a labor allowance per the 
published schedule.  After 10 years, there will be a proportionate charge based upon the time the defective assembly 
was in service.  The proportionate charge will be equal to the appropriate percentage of the trade list price of such 
pressure vessel at the time the warranty claim is made as determined in the following: 

 

YEAR: 1

st

 11

th

 12

th

 13

th

 14

th

 15

th

 16

th

 17

th 

Percent of Trade list Price: 

 

0%  5%  10% 15% 20% 25% 30% 35% 

 
YEAR: 18

th

 19

th

 20

th

 21

st

 22

nd

 23

rd

 24

th

 25

th

 

Percent of Trade list Price: 

 

40% 45% 50% 55% 60% 65% 70% 75% 

 
YEAR: 25

TH

 and Above: 75% of Trade list Price 

 

IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY SHALL BE LIMITED TO 

THE DURATION OF THE EXPRESS WARRANTY-ENERGY KINETICS EXPRESSLY DISCLAIMS AND EXCLUDES ANY 
LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED 
WARRANTY. 

 

This Warranty gives you specific legal rights and you may have, also, other rights which vary from state to state. 

 

EXCEPTIONS AND EXCLUSIONS

 

1.  The warranty is subject to the condition that the residential boiler must have been installed and serviced in 

accordance with Energy Kinetics instructions, the basic BOCA Building Code, local statutes and ordinances and 
accepted good industry practice. 

2.  This warranty does not cover components that are part of the heating system but which were not furnished by 

Energy Kinetics. 

3.  This warranty does not cover the workmanship of any installer of Energy Kinetics residential water boiler.  In 

addition, it does not assume any liability of any nature for unsatisfactory performance caused by improper 
installation. 

4.  This warranty does not cover improper burner adjustments, control settings, care or maintenance. 
5.  This warranty does not cover any labor for removal or reinstallation of the alleged defective part, transportation to 

Energy Kinetics if necessary and other materials necessary to perform the exchange. 

6.  This warranty does not cover failure of the pressure vessel other than defects in material or workmanship and 

shall specifically exclude any other reason including but not limited to  a) lack of water  b) freezing  c) excessive 
pressure  d) floods  e) fire  f) acts of God  g) corrosion of internal or fireside surfaces  h) improper water 
conditioning  I) improper maintenance of external fireside surfaces  j) operation with defective fuels or other 
additives which cause deposits to collect or corrosion to occur in or on the pressure vessel. 

 

Содержание System 2000 EK1 Frontier

Страница 1: ...NSTRUCTION MANUAL AND ACCESSORY INSTRUCTIONS VISIBLY NEXT TO THE BOILER USING THE SUPPLIED POUCH HOMEOWNER USER READ AND SAVE THIS INSTRUCTION MANUAL AND ACCESSORY INSTRUCTIONS FOR FUTURE REFERENCE MH...

Страница 2: ...n or equipment damage from corrosive flue products Do not store or use gasoline or other flammable vapors or liquids near or in the same room as the burner Do not use or store laundry products paint v...

Страница 3: ...r 20 Oil Burner Operation 8 Chimney Venting 21 Digital Manager Operation Summary 9 L Vent Chimney 22 Digital Energy Manager Check 9 Sidewall Venting 23 2 Minute Diagnostics 9 Fuel Systems 23 Additiona...

Страница 4: ...to relight If the burner relights successfully then no further action is needed If the burner goes into lock out again contact a qualified service agency for help ANNUAL MAINTENANCE The SYSTEM 2000 bo...

Страница 5: ...L CODES THAT MAY DIFFER FROM THIS MANUAL AND IN ACCORDANCE WITH THE FOLLOWING CODES AS APPLICABLE N F P A No 70 National Electrical Code A N S I N F P A No 31 Installation of Oil Burning Equipment A N...

Страница 6: ...s completed at the end of each heat call virtually eliminating off cycle losses Your System 2000 holds a minimal quantity of water so it begins to supply heat in about 90 seconds This rapid response m...

Страница 7: ...o the freight carrier before installation The receiver is responsible for following the claims procedure of the freight carrier The freight carrier is responsible for taking prompt action on all claim...

Страница 8: ...5 feet of straight pipe For example if three 90 degree elbows are used then the length of pipe run may increase to 35 feet For longer runs up to 40 feet with up to five 90 degree elbows immediately in...

Страница 9: ...to clean out doors that are located out of doors CAUTION If liner is not sound or if existing tile liner fails to contain intermittent condensation or if excessive debris is found at the base of the...

Страница 10: ...position This enables the Inducer light and allows the Digital Manager to control the inducer Refer to Digital Manager Section for option switch settings and inducer timing details FUEL SYSTEMS NOTICE...

Страница 11: ...o insert the burner head 2 3 8 into the boiler Energy Kinetics installs a ceramic sleeve the amulet to protect the burner head from the heat of combustion and then seals the air tube flange joint with...

Страница 12: ...st be disconnected to allow door to swing down BOILER MOUNTING on STANDARD BASE FIG 2B The back support bar should be mounted to the holes just in front of the 2 slot Line up the rear holes in the leg...

Страница 13: ...nergy Kinetics to obtain piping and wiring instructions for alternate applications such as hydronic heating radiant heating domestic hot water swimming pool heating multiple boilers injection loops et...

Страница 14: ...TER TREATMENT Addition of boiler water treatment is recommended to reduce lime buildup inside the boiler Energy Kinetics recommends addition of one quart of 8 Way Boiler Treatment per 30 gallons syste...

Страница 15: ...for an extended period of time LINE VOLTAGE WIRING DIAGRAMS WIRING and CONTROLS The Frontier Heating System is furnished with controls and basic accessories as illustrated and described in this manua...

Страница 16: ...ir handler wiring heat pump wiring isolation relays for thermostats and isolation relays for heat motors or circulators etc The single 24 volt 50VA transformer is suitable for the Digital Manager and...

Страница 17: ...ting 3 Inducer Purge Temp ON stop purge when Boiler Return Temp cools down to 120 o F OFF stop purge when Boiler Return Temp cools to140 o F See Switch 4 4 Inducer Purge Time ON 3 minutes minimum OFF...

Страница 18: ...f of manager Attach one lead from zone valve or relay to corresponding zone output and the other lead to 24VAC on lower half 5 Option switches control energy recovery for extra zone outputs see Locati...

Страница 19: ...GER MAKE CERTAIN THE FOLLOWING REQUIREMENTS HAVE BEEN SATISFIED BEFORE START UP 1 The boiler and piping are completely filled with water 2 Re check wiring to ensure that it is correct and in accordanc...

Страница 20: ...l start to rise A slight odor is common on initial light off as combustion chamber and converter surfaces warm for the first time 5 NOTICE Perform smoke test immediately after light off Smoke test sho...

Страница 21: ...is turning or vent blockage 1 DANGER Verify proper operation of high limit aquastat a With a Digital Manager i Remove all heat and hot water calls No input lights on left side of manager ii Turn Syst...

Страница 22: ...operating aquastat and will turn off the burner if return temperature reaches 170 F operating limit The zone outputs will open when the return temperature is above 140 F and close zone outputs when t...

Страница 23: ...eck the zone valve and it s wiring For hot water check the hot water relay wiring and the bronze circulator This is the sidewall vent inducer output light This light will only operate if option switch...

Страница 24: ...e output wiring check all wiring re connect quick connector and repeat steps 1 2 and 3 until problem is resolved You re done The manager is functioning properly Remember to reset thermostats to origin...

Страница 25: ...unctioning of each output zone never apply a jumper to the Digital Manager output terminals The easiest way to test each zone output is to remove the red sensor lead The Manager should go into Service...

Страница 26: ...d heat cycle Does boiler return heat up properly NO Check circulator Possible closed or blocked bypass YES Intermittent problem Check low voltage wiring for tightness from Manager through relay board...

Страница 27: ...iate jumper action below with Manager in place BURNER Jumper BB or TT on burner control Burner will run on limit whenever Manager calls circulator The boiler may overheat slightly during energy recove...

Страница 28: ...available for nominal rebuild charge and require the return of a Manager Manager must be rebuildable Preheat cycle zones will open when boiler return is above 140o F 150o F if option switch 1 is on Re...

Страница 29: ...ing and insert it approximately 8 into the boiler Connect this tube to your test probe using a piece of hose Clean boiler flue passage if the draft difference between the flue box 1 and over fire test...

Страница 30: ...Sidewall Vent Only A Remove power from the inducer Option switch 2 on a Digital Manager B Start burner Safety lockout should occur in approximately 1 minute C Restore power to the inducer Step 8 Check...

Страница 31: ...boiler with the exhaust opening in the 3 o clock position Chamber outlet must fit behind or alongside the metal tab supply nipple in the top rear of the boiler 7 With chamber fully inserted slightly...

Страница 32: ...98 Amulet ceramic sleeve 10 0416F 10 0435F Plate Heat Exchanger PART NO DESCRIPTION PART NO DESCRIPTION 10 0418D Digital Manager 10 0438C 0010 Cartridge EK2 Main Circ C I 10 0434H Air Vent 10 0465 Pri...

Страница 33: ...le After 10 years there will be a proportionate charge based upon the time the defective assembly was in service The proportionate charge will be equal to the appropriate percentage of the trade list...

Страница 34: ...homeowner agrees to make all reasonable efforts to settle any disagreement arising in connection with this claim before resorting to legal remedies in courts If you have any questions about the cover...

Отзывы: