![Energizer Force 3.6S Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/energizer/force-3-6s/force-3-6s_installer-manual_2410142016.webp)
________________________________________________________________________________________________________
Energizer
Solar Inverter | Installer Manual [15]
•
WiFi/LAN/GPRS (optional)
The inverter has an interface for WiFi/LAN/GPRS devices that allows this device to collect information from the inverter;
including its working status, performance etc., and update that information to the monitoring platform (the WiFi/LAN/GPRS
device is available to purchase from your local supplier).
Connection steps:
1. For GPRS device: Insert the SIM Card (please refer to the GPRS product manual for more details).
2. For LAN device: Complete the wiring between router and LAN device (please refer to the LAN product manual for
more details).
3. Plug the WiFi/LAN/GPRS device into “WiFi/GPRS” port at the bottom of the inverter.
4. For WiFi device: Connect the WiFi with the local router, and complete the WiFi configuration (please refer to the WiFi
product manual for more details).
5. Set-up the site account on the monitoring platform (please refer to the monitoring user manual for more details).
•
CT (optional)
The
Energizer
solar inverter has an integrated export management function. To enable this function, a power meter or CT
must be installed. The CT should be clamped on the main live line of the grid side. The arrow on the CT should be pointing
towards the grid. The white cable connects to CT+, and the black cable connects to CT-.
Export limitation setting:
Short press the touch key to switch display or make the 1. Long press the touch key to confirm your setting.
Note!
For a precise reading and control of power, a meter can be used instead of a CT.
If the CT is fitted in the wrong orientation, anti-backflow function will fail.