![Energizer Force 3.6S Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/energizer/force-3-6s/force-3-6s_installer-manual_2410142012.webp)
________________________________________________________________________________________________________
Energizer
Solar Inverter | Installer Manual [11]
-
Insert the expansion tubes into the holes and tighten them. Install the bracket with the expansion screws.
Step 2: Match the inverter with the wall bracket
-
Hang the inverter over the bracket, slightly lower the inverter, and make sure the 2 mounting bars on the back are
fixed with the 2 grooves from bracket properly.
5.6 Wiring Steps
Step 1: PV String Connection
This series of
Energizer
solar inverters can be connected with 2-strings of PV modules. Please select suitable PV modules
with high reliability and quality. Open circuit voltage of module array connected should be less than 600V, and operating
voltage should be within the MPPT voltage range.
Note!
Please choose a suitable external DC switch if the inverter does not have a built-in DC switch.
Warning!
PV module voltage is very high and within a dangerous voltage range, please comply with the electric
safety rules when connecting.
Warning!
Please do not make PV positive or negative to ground!
Note!
Ensure the PV modules are the same type, have the same output and specifications, are aligned
identically, and are tilted to the same angle. To save cable and reduce DC loss, we recommend
installing the inverter as near to the PV modules as possible.