Grid Connection 

This series of 

Energizer

 solar inverters are designed for single-phase grid. Voltage range is 220/230/240V; 

frequency is 50/60Hz. Other technical requests should comply with the requirement of the local public grid. 

 

Model 

Force 3S 

Force 3.6S 

Force 4.6S 

Force 5S 

Force 6S 

Cable 

4mm² 

4mm² 

6mm² 

6mm² 

6mm² 

Micro-Breaker 

25A 

25A 

40A 

40A 

40A 

 

 

 
 
 
 
 

WARNING! 

A micro-breaker for max output overcurrent protection device must be installed between inverter and grid, 

and the current of the protection device is referred to the table above, any load SHOULD NOT be 

connected with the inverter directly.

 

 

Step 3: AC Wiring 

• 

Check the grid voltage and compare with the permitted voltage range (refer to technical data). 

• 

Disconnect the circuit-breaker from all the phases and secure against reconnection. 

• 

Trim the wires: 

-

 

Trim all the wires to 52.5mm and the PE wire to 55mm. 

-

 

Use the crimping pliers to trim 12mm of insulation from all wire ends as below. 

 

 

 

 

 

 

• 

Separate the AC plug into three parts as below. 

-

 

Hold middle part of the female insert, rotate the back shell to loosen it, and detach it from female inset. 

-

 

Remove the cable nut (with rubber insert) from the back shell. 

   

 

   

• 

Slide the cable nut and then the back shell onto the cable. 

 

 

 

 

L: Brown/Red Wire 

N: Blue/Black Wire 

PE: Yellow & Green Wire 

Please refer to local cable type and color for actual installation. 

Содержание Force 3.6S

Страница 1: ...________________________________ Energizer Solar Inverter Installer Manual 0 INSTALLER MANUAL This guide describes how to use and install Energizer Solar Inverters To prevent improper operation before...

Страница 2: ...3 4 Dimensions 6 4 Technical Data 7 4 1 DC Input 7 4 2 AC Output 7 4 3 Efficiency Protection and Standard 8 4 4 General Data 8 5 Installation 9 5 1 Packing List 9 5 2 Preparation 9 5 3 Installation S...

Страница 3: ...echnicians only 1 3 Symbols Used The following types of safety instructions and general information that appear in this document are as described below Danger Danger indicates a hazardous situation wh...

Страница 4: ...d operation may lead to serious safety and shock hazards or equipment damage Before connecting the inverter to the power distribution grid contact the local power distribution grid company to get appr...

Страница 5: ...nts to limit the current in grounding conductors for the safety The default value for higher speed personal protection is 30mA and 300mA per unit for lower speed fire safety Installation and Selection...

Страница 6: ...ter and the meter distribution system SPD test impulse D1 for signal line according to EN 61632 1 All DC cables should be installed to provide as short a run as possible and positive and negative cabl...

Страница 7: ...minals Introduction Item Description A DC Connector B DC Connector C DC Switch Optional D Waterproof Lock Valve E Communication Port F USB Port For Upgrade G WiFi GPRS LAN Optional H AC Connector I Gr...

Страница 8: ...Current input A input B A 15 15 MPPT Voltage Range Vdc 80 550 80 550 80 550 80 550 80 550 Start up Voltage V 120 120 120 120 120 No of MPP Trackers 2 2 2 2 2 Strings Per MPP Tracker 1 1 1 1 1 4 2 AC...

Страница 9: ...lf Consumption night W 1W Monitoring Module optional External WIFI Lan GPRS optional Communication Meter CT DRM USB update RS485 Display LCD Panel Touch Key iOS App Android App Web Portal Warranty 10...

Страница 10: ...up during installation and operation To avoid overheating always make sure the air flow around the inverter is not blocked Do not install in places where gas or flammable substances may be present Avo...

Страница 11: ...t set 8mm Crimping pliers Stripping pliers Screwdriver 5 5 Installation Steps Step 1 Fix the bracket on the wall Choose the wall location you want to install the inverter Place the bracket on the wall...

Страница 12: ...strings of PV modules Please select suitable PV modules with high reliability and quality Open circuit voltage of module array connected should be less than 600V and operating voltage should be withi...

Страница 13: ...d ensure all conductor strands are captured in the pin contact Crimp pin contact by using a crimping plier Put the pin contact with striped cable into the corresponding crimping pliers and crimp the c...

Страница 14: ...tion device is referred to the table above any load SHOULD NOT be connected with the inverter directly Step 3 AC Wiring Check the grid voltage and compare with the permitted voltage range refer to tec...

Страница 15: ...e bayonet out of the slot with a small screwdriver or the unlock tool and pull it out or unscrew the threaded sleeve then pull it out 5 7 Earth Connection Screw the ground screw with screwdriver as sh...

Страница 16: ...iFi GPRS port at the bottom of the inverter 4 For WiFi device Connect the WiFi with the local router and complete the WiFi configuration please refer to the WiFi product manual for more details 5 Set...

Страница 17: ...g devices Meter optional The inverter has integrated export limitation functionality To use this function a power meter or a CT must be installed For Meter installation please install it on the grid s...

Страница 18: ...se refer to following steps a Please contact our service support team to get the latest firmware and copy the files to U disk using the following file path Master Update master xxxxx_Master_Vx xx hex...

Страница 19: ...fault code Isolation fault will be displayed on the inverter screen and the RED LED indicator will light up Reactive Power Regulation for Voltage Variation Volt VAr Mode Details of how to enable this...

Страница 20: ...possible inverter states indicating that the inverter has started up successfully Waiting Inverter is waiting to check the DC input voltage from panels is greater than 80V lowest start up voltage but...

Страница 21: ...Inverter Switch Off Please follow the below steps to switch off the inverter a Switch off the inverter AC isolation switch b Switch off the DC isolation switch and allow 5 minutes for the inverter to...

Страница 22: ...________________________________________________________________________________________________________ Energizer Solar Inverter Installer Manual 21 6 2 Function Tree...

Страница 23: ...V with DC After the LCD switches off reconnect and check again EEPROM Fault Disconnect PV PV with DC After the LCD switches off reconnect and check again GFC Fault Disconnect DC and AC connector check...

Страница 24: ...OCP Turn off the PV and grid reconnect them PLL Fault System will reconnect if the utility is back to normal PV OVP Check the panel s open circuit voltage whether the value is similar or already 550Vd...

Страница 25: ...dy including a description of your system installation the model and serial number and any issues and troubleshooting you have already attempted 7 3 Routine Maintenance Safety check A safety check sho...

Страница 26: ...ckaging If it is no longer available you can use an equivalent box that meets the following requirements Suitable for loads more than 30 kg Contains a handle Can be fully closed 8 3 Storage and Transp...

Страница 27: ...Email hello energizersolar com Website www energizersolar com 2021 Energizer Energizer and certain graphic designs are trademarks of Energizer Brands LLC and related subsidiaries and are used under li...

Отзывы: