![Energie ECO 200i Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/energie/eco-200i/eco-200i_technical-manual_2409984036.webp)
Technical Manual
36
ECO
6.3 Interface Symbols
Equipment in ECO operating mode
Equipment in AUTO operating mode
Equipment in BOOST operating mode
Compressor
Electrical heater
Unlocked keyboard
Locked keyboard
Timer activated after error of LP
Disinfect function is active
Holiday mode is active
Error alarm (visible on display during error)
Error memory (visible on display during 24h)
Water temperature scale in storage water heater
T
A
Electrical heater is activated when P02 < P08 and/or P07 < Temp.
S3 (Auto Mode)
T
C
Electrical heater is activated when time for continuous running of
Compressor is over T05 (Auto Mode)
LP
Electrical heater is activated by opening of LP contact (Auto/Boost
Mode)
M
Electrical heater is manually activated
6.4 Operating Modes
ECO
is programmed to work in 3 running modes,
ECO
,
AUTO
and
BOOST
, which are
summarized in this table:
The equipment is configured by default to work in the “
ECO
” operating mode. If the user
finds it necessary to change the operating mode, he must carry out the following procedures:
Unlock the keyboard and press the
Menu
key; on the ▲ ▼ keys, scroll through the menu
and select
F03
, access the submenu and select the desired operating mode
Modo
Simbologia
Funcionamento
ECO
Normal running as Thermodynamic System
AUTO
Optimized management of running of Thermodynamic System and/or
Electrical Heater (support)
BOOST
Running of Thermodynamic Electrical Heater (support)