Energie ECO 200i Скачать руководство пользователя страница 1

 

 

ECO 

200i | 250esm | 250i | 250ix | 300esm | 300i | 300ix 

200is | 250is | 250isx | 300esms | 300is | 300isx | 500is | 500isx 

 

 

 

 

 

TECHNICAL MANUAL

 

EN

 

European Certification

 

EN 60335-1

 

EN 60335-2-21

 

EN 60335-2-40

 

Directives

 

2006/95/CE

 

Revision 16

 

Version 0

 

Date 07/06/2022

 

Содержание ECO 200i

Страница 1: ...250ix 300esm 300i 300ix 200is 250is 250isx 300esms 300is 300isx 500is 500isx TECHNICAL MANUAL EN European Certification EN 60335 1 EN 60335 2 21 EN 60335 2 40 Directives 2006 95 CE Revision 16 Versio...

Страница 2: ......

Страница 3: ...vations that will promote power saving in our products Your choice has demonstrated your good sense and concern with power consumption a matter that affects the environment We have taken on a permanen...

Страница 4: ...st Corrosion if applicable 19 3 5 5 Dielectric Joint enamelled boilers 19 3 5 6 Expansion Vessel 20 3 5 7 Safety Group 20 3 5 8 Pressure Reducing Valve 20 4 INSTALLATION 21 4 1 Attachment of the Panel...

Страница 5: ...rating Mode 37 6 5 Extra Modes 37 6 5 1 DISINFECT Function 37 6 5 2 VACATION Mode 38 6 5 3 PV Mode 38 7 SYSTEM MENU 39 8 ERRORS 39 9 PARAMETERS DESCRIPTION 40 10 PROBE CHART 41 11 TROUBLESHOOTING 41 1...

Страница 6: ...f the power supply cable is damaged it must be replaced by the manufacturer by its customer service or by staff with similar training in order to avoid any danger ECO will only operate if the storage...

Страница 7: ...ualified person WARNING DANGER In order to avoid any danger due to the untimely rearming of the thermal circuit breaker the device must not be powered by an external switch such as a timer or connecte...

Страница 8: ...ion of material Refrigerant The refrigerant used in the entire process is R134a CFC free non inflammable and without harmful effects to the ozone layer However according to the law the fluid in this e...

Страница 9: ...h fixing elements and the other with the thermo accumulator and the attached thermodynamic group The packages contain 1 Thermodynamic solar panel with fastening elements 2 Storage water heater 3 Therm...

Страница 10: ...ng the water heater and the thermodynamic block must be transported in an upright position and in the correct direction Horizontal transport or with the equipment turned upside down can cause serious...

Страница 11: ...the R134a ecological refrigerant evaporates inside the solar panel The absence of glass on the panel allows to increase the thermal exchanges by convection After passing through the panel the R134a is...

Страница 12: ...Monophase 50 ou 60 Fuse Main Electrical Heater A 10 10 Working Temperature C 5 45 PERFORMANCE Tapping Porfile L XL XL XL XL Coefficient of Performance COP Air 2 C 2 8 2 9 2 9 2 9 2 9 Air 7 C 3 1 3 2...

Страница 13: ...ou 60 Fuse Main Electrical Heater A 10 10 Working Temperature C 5 45 PERFORMANCE Tapping Porfile L XL XL XL XL XXL XXL Coefficient of Performance COP Air 2 C 2 76 2 8 2 8 2 8 2 8 2 9 2 9 Air 7 C 3 09...

Страница 14: ...appliance The safety device must be in compliance with the standard EN 1487 2002 maximum pressure 7 bar 0 7 MPa Water must not be stopped from flowing from the safety device to the deposit by any sor...

Страница 15: ...107 102 Cold Water C G 1 M 231 236 635 Coil Outlet D 435 436 Instrumentation E G 1 M 690 636 1525 Coil Inlet F G F 840 840 782 855 782 Recirculation G G 1 M 1025 1096 1093 Magnesium Anode H G F 905 13...

Страница 16: ...D Plate Any contact with the installer or manufacturer must be accompanied by Model Serial number Date of production The provision of these data will facilitate all communication and consequently a fa...

Страница 17: ...he connection side Left Panel Right Panel The panels have the following pipe diameters 3 8 aspiration upper joint 1 4 liquid lower joint In the case of panel equipment the refrigerant connections are...

Страница 18: ...onnected to the condenser which surrounds the water heater through two One Shot valves Storage Water Heater The domestic hot water storage heater is vertical resting on the ground Thermal insulation i...

Страница 19: ...s this value the thermostat switches off the backup electrical heater Switching on is done manually by qualified staff after analysing the reasons for the switch off 3 5 3 Temperature Probe The purpos...

Страница 20: ...e The pressure reducing valve must always be installed upstream from the safety device and ready to activate in situations when the pressure in the circuit exceeds 3 bar 0 3MPa This valve comes with a...

Страница 21: ...unlight exposure the panels Should have a pitch between 10 and 85 relative to the horizontal plane and preferably oriented to the south The panel already comes with 6 holes for M8 in the lateral skirt...

Страница 22: ...lope of 45 The profile must be fixed to the base eg tile using a plastic anchor and M6 screw provided The panel is fixed to the profiles using the M6 screws and the respective nuts and washers The pan...

Страница 23: ...respect this parameter can lead to the exclusion of the warranty Make sure that the support surface is sufficient to accommodate the weight of the water filled water heater Provide at least 500mm of...

Страница 24: ...purpose Refrigerant connections must be thermally insulated to prevent burns and to ensure optimum system performance The system has an R134a fluid preload 4 4 1 Connections to the panel 1 Thermodyna...

Страница 25: ...2 Thermodynamic Panels a Prepare the copper pipe removing the protective caps from the extremities b Place the extremity of the pipe upside down cut the appropriate size of pipe and sand the rough ed...

Страница 26: ...ctions Exit of the panels the same symmetry accuracy in the length of the tubes is not required The same should be done by chipping or with a T as shown in the following image properly isolated The ty...

Страница 27: ...of the pipe employed according to table in point 4 4 1 Insufficient torque will cause leaks of refrigerant Excessive torque on the coupling will damage the edge of the pipe and cause leaks 4 4 3 Conne...

Страница 28: ...eed to the following points The water heater thermodynamic group is filled with fluid The closed valves ensure that the fluid does not escape during the next steps All connections must be isolated 1 3...

Страница 29: ...ate a vacuum with the vacuum pump plugged to the inlet of the 3 way pressure valve as depicted keeping the valves completely shut The vacuum should be at least 30min for installation of one panel and...

Страница 30: ...t a complementary load of gas follow these steps a Place the cooling fluid tank on a scale with a 10 g precision and take note of the weight b Connect the hose of the cooling fluid tank R134a to the i...

Страница 31: ...mm from the pavement to allow visual inspection WARNING We recommend the installation of a shut off section valve between the gate valve and the coupling to the storage water heater for the purpose of...

Страница 32: ...cal Manual 32 ECO 4 6 1 Wiring diagram 1 Thermodynamic Panel S1 Temperature probe Comp Compressor LP Low pressure switch R1 Support electrical heater D1 Circuit breaker TB Safety thermostat Q1 Differe...

Страница 33: ...anual 33 ECO 4 6 1 Wiring diagram 2 Thermodynamic Panels S1 Temperature probe Comp Compressor LP Low pressure switch R1 Support electrical heater D1 Circuit breaker RL Relay Q1 Differential TB Safety...

Страница 34: ...hether the installation is set up according to the recommendations and that everything is in conformity then you may plug your equipment to the power supply After switching on your equipment you shoul...

Страница 35: ...itch on off Switch on and off controller CANCEL Exit ESC function to exit menu submenu or cancel a function OK OK Confirmation Confirm parameters within menus or submenus LOCK Lock Unlock Lock or unlo...

Страница 36: ...o Mode LP Electrical heater is activated by opening of LP contact Auto Boost Mode M Electrical heater is manually activated 6 4 Operating Modes ECO is programmed to work in 3 running modes ECO AUTO an...

Страница 37: ...N OFF 6 4 3 BOOST Operating Mode In BOOST operating mode the equipment runs as a Heat Pump Electrical Heater and the running of the electrical heater is simultaneous with the Heat Pump This mode enabl...

Страница 38: ...on offers the possibility to raise the water temperature when an alternative electrical energy source is available solar photovoltaic wind or other increasing the efficiency of the heat pump and makin...

Страница 39: ...emperature Water temperature in storage water heater is too hot Check that there is no anomaly in the electronic board such as a damaged relay Temperature probes in short circuit Measure internal resi...

Страница 40: ...ctivate electrical heater 1 40 Value 16 C Parameter ON T01 Delay time to compressor starts running 1 20 2 min T05 Maximum time compressor running AUTO 6h 15h Value 12 horas Parameter ON T07 Delay time...

Страница 41: ...function Check the presence of error on electronic board and consult the table of errors Use of large amount of hot water Set BOOST mode and wait for water heating Low temperature programmed in the Se...

Страница 42: ...g of expansion tank Pressure in circuit is high if the leak is continuous Check the throttle valve if there is one installed Installation of a throttle valve if it lacks one Consumption abnormally hig...

Страница 43: ...pressure for example open a hot water tap Unscrew the anode with a suitable tool Check the level of wear of the anode and replace it if necessary If the diameter of the anode is less than 15mm it will...

Страница 44: ...a separate collection centre for electrical electronic equipment or returned to the retailer at the time of purchasing new equipment The end user is responsible for delivering the end of life device...

Страница 45: ......

Страница 46: ......

Страница 47: ...n any form of intervention by unauthorized technicians has the appearance of modifications and or if the series number appears to have been removed or erased The equipment should be installed by quali...

Страница 48: ......

Страница 49: ...NOTES...

Страница 50: ......

Страница 51: ......

Страница 52: ......

Отзывы: