Enerdrive ePRO Inverter / Charger Owners Manual
Page 32
6. Troubleshooting Guide
Please see the table below if you experience any problems with the
ePRO Combi and/or the installation.
Problem
Possible cause
Remedy
ePRO Combi is not
working at all.
Main switch in O
ff
(0) position.
Push the power switch in
the ‘I’ or ‘II’ position.
Remote switch or Universal
Remote Control have
deactivated the ePRO Combi.
Activate the ePRO Combi
remotely or check DIP switch
8 or 10 for correct setting.
Poor contact between the
ePRO Combi battery wires
and the battery terminals.
Clean battery terminals or
ePRO Combi wire contacts.
Tighten battery terminal screws.
Blown DC fuse.
Check battery fuse or
internal ePRO Combi fuse
(EPC1600-1800 only).
Very poor battery condition.
Replace battery.
The charger mode
is not working
(AC transfer
switch does not
activate either).
The AC input voltage
or frequency are out of
range or too unstable.
Make sure that the AC input
voltage is between 185V
- 270V and the frequency
between 45Hz – 65Hz
(assuming standard settings)
Charger mode and/or the AC
transfer switch are disabled
during setup using Dashboard.
Enable Charger mode and the AC
transfer switch using Dashboard.