Enerdrive ePRO Inverter / Charger Owners Manual
3.2 Factory Default Parameter Settings
The table below shows an overview of the most relevant factory
parameter settings, as stored in the ePRO Combi. These settings are
based on an average application. Enerdrive cannot guarantee that these
are correct for your speci
fi
c application. Please check all parameters
carefully, especially the battery charging voltages.
Parameter
Inverter frequency
Value
50Hz
Description
Output frequency in inverter mode. Can be set to 50Hz or 60Hz
Con
fi
gurable by
DIP switch (DIP 2) and Dashboard
Parameter
Inverter voltage
Value
230V
Description
Output voltage in inverter mode. Can be set from 200V to 240V
Con
fi
gurable by
Dashboard
Parameter
Low Battery Protect
Value
On
Description
Enables or disables low battery protection with user programmable
shutdown, restart and delay values (standard respectively 10V, 12V
and 5 seconds). Turning Low Battery Protect o
ff
, results in immediate
inverter shutdown when the battery voltage is less than 8.0V.
Con
fi
gurable by
DIP switch (DIP 3) and Dashboard
Parameter
Automatic Stand By (ASB)
Value
O
ff