OPERATING INSTRUCTIONS

PREPARING FOR OPERATION

1.

Check the heater for possible shipping damage. If any is
found, immediately notify the factory.

2.

Follow all of the “Precautions”.

3.

Connect the POL fitting of hose and regulator assembly
to the propane cylinder by rotating the POL nut
counterclockwise into the propane cylinder’s valve outlet and
securely tighten with a wrench.

4.

Connect the hose to the heater by rotating the hose fitting
clockwise.

5.

Securely tighten all gas connections.

6.

Open the cylinder’s gas valve and check all gas connections
with a soap and water solution. DO NOT USE A FLAME.

7.

Connect power cord to well-grounded 115V, 60 Hz, 1Ø
source of power.

8.

When using an extension cord, make certain that it is a
3-wire (grounded) cord of proper wire size.

170FAVT 

(WITH THERMOSTAT)

START 

1.

Slowly open the main valve at propane cylinder to
prevent excess flow check valve from closing.

2.

Set thermostat to full on.  Heater will ignite
automatically.

3.

Adjust ball valve on control panel to desired burn rate.

4.

Set thermostat to desired temperature. Heater will turn
off and  on automatically as the temperature varies in
the heater area.

STOP

1.

Securely close valve on the propane cylinder.

2.

Continue to operate heater until all fuel in the hose has
burned.

3.

Unplug the heater from electrical supply.

     

RESTART AFTER SAFETY SHUTDOWN

1.

Securely close valve at propane cylinder. Unplug heater.

2.

Wait 5 minutes.

3.

Restart following “Start” procedure.

MAINTENANCE AND STORAGE

1.

The heater should be inspected before each use, and at least
annually by a qualified person.

2.

Before each use, check the soft “O” ring seat at the bullnose
of the POL fitting. If the “O” ring is cut, scuffed, or otherwise
damaged, replace it with part number F273786.

3.

Turn off the gas at the LP-gas supply cylinder(s) when the
heater is not in use.

4.

When the heater is to be stored indoors, the connection
between the LP-gas supply cylinder(s) and the heater must
be disconnected and the cylinder(s) removed from the heater
and stored out of doors and in accordance with Chapter
5 of the standard for Storage and Handling of Liquefied
Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural
Gas and Propane Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has 
been modified or is not functioning properly.  
When the heater is working properly:

The flame is contained within the heater.

The flame is essentially blue with perhaps some
yellow tipping.

There is no strong disagreeable odor, eye burning or
other physical discomfort.

There is no smoke or soot internal or external to the
heater.

There are no unplanned or unexplained shut downs
of the heater.

The parts lists and wiring diagram show the heater as it was 
constructed. Do not use a heater which is different from 
that shown. In this regard, use only the hose, regulator and 
cylinder connection fitting (called a POL fitting) supplied 
with the heater. 

IMPORTANT

 Match the color stripe on the 

hangtag attached to the hose assembly with the color on the 
label located near the propane inlet fitting on the heater. Do 
not use alternates. For this heater, the regulator must be set 
as shown in “specifications”. If there is any uncertainty about 
the regulator setting, have it checked.

A heater which is not working right must be repaired, but 
only by a trained, experienced service person.

In-warranty products will be repaired with no charge for 
either parts or labor. Please include a brief statement 
indicating date, place of purchase, the nature of the problem 
and proof of purchase.

Out-of-warrranty products will be repaired with a charge for 
parts and labor.

CAUTION

:

 

Failure to unplug the unit may result in unexpected

 

         operation.

 

Содержание HeatStar HS170FAVT

Страница 1: ...t be performed by a qualified service agency This is an unvented gas fired portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided...

Страница 2: ...E THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS WARNING CARBON MONOXIDE CAN KIL...

Страница 3: ...odified from its original condition 3 Use only propane gas 4 Use only VAPOR WITHDRAWAL propane supply If there is any question about vapor withdrawal ask your propane dealer 5 Mount the propane cylind...

Страница 4: ...o not use this heater for heating human living quarters Do not use in unventilated areas The flow of combustion and ventilation air must not be obstructed Proper ventilation air must be provided to su...

Страница 5: ...ed replace it with part number F273786 3 Turn off the gas at the LP gas supply cylinder s when the heater is not in use 4 When the heater is to be stored indoors the connection between the LP gas supp...

Страница 6: ...Length in Feet Amps 25 50 100 150 5 6 18 16 14 12 6 8 18 16 12 10 8 12 18 14 12 10 10 12 16 14 10 8 12 14 16 12 10 8 WARNING When using a thermostat controlled heater its exit area should be protecte...

Страница 7: ...e Assembly 1 26152 20 Hose Assembly 20 HS only 1 14 26257 Regulator 28 WC 1 15 26433 POL Excess Flow Valve 1 16 26122 Male Fitting Conn 1 3 8MPT x 3 8SAE FLR 17 26101 Solenoid Valve Goyen 1 18 28775 F...

Страница 8: ...o 44135 Include your name address and telephone number and include details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our...

Страница 9: ...auffage teignez toute flamme nue Fermez l alimentation en gaz l appareil L entretien doit tre effectu par un fournisseur de services d entretien qualifi Cet appareil de chauffage portatif aliment au g...

Страница 10: ...DES PARTICULES DE POUSSI RE OU DES PRODUITS CHIMIQUES INCONNUS AVERTISSEMENT LE MONOXYDE DE CARBONE PEUT VOUS TUER L UTILISATION D UN CHAUFFAGE PORTABLE DANS UNE ZONE RECHARGEE PEUT PRODUIRE DU MONOXY...

Страница 11: ...ilisez uniquement une alimentation au propane LIMINATION DES MANATIONS Si vous avez des questions propos de l limination des manations consultez votre d taillant de gaz propane 5 Installez les bonbonn...

Страница 12: ...air de ventilation Consultez la rubrique portant sur les sp cifications techniques dans le manuel de l appareil ou sur la plaque de donn es de l appareil ou communiquez avec le fabricant pour obtenir...

Страница 13: ...ppareil de chauffage Il ne se produit pas d arr ts impr vus ou inexpliqu s de l appareil La liste des pi ces et le sch ma de c blage pr sentent l appareil de chauffage tel qu il a t construit N utilis...

Страница 14: ...ue au bas du tableau 2 D placez vous en ligne droite vers le haut jusqu au temps de fonctionnement souhait c t gauche du tableau 3 Notez la dimension de la bonbonne requise Tous les appareils de chauf...

Страница 15: ...au point de charge 1 16 26122 Connexion raccord m le 3 8MPT x 3 8 SAE FLR 1 17 26101 lectrovanne Goyen 1 18 28775 Raccord troit 1 19 28777 Soupape de r glage du taux de combustion 1 20 28776 Raccord c...

Страница 16: ...ous galement la date d achat et le nom et l adresse du d taillant de qui vous avez achet le produit Ce qui est nonc ci dessus constitue la responsabilit totale de l entreprise Il n existe aucune autre...

Страница 17: ...ado por una agencia de reparaci n calificada Este calentador port til a gas no tiene una fuente propia de ventilaci n Utiliza el aire ox geno del rea en la cual se emplea Debe suministrarse el aire ne...

Страница 18: ...IONES NUNCA USE EL CALENTADOR EN ESPACIOS QUE CONTIENEN O PODR AN CONTENER COMBUSTIBLES VOL TILES O PRODUCTOS COMO GASOLINA SOLVENTES DILUYENTE DE PINTURA O PRODUCTOS QU MICOS DESCONOCIDOS ADVERTENCIA...

Страница 19: ...de propano con RECUPERACI N DE VAPOR Si tiene alguna pregunta sobre la recuperaci n de vapor consulte al proveedor de propano 5 Monte los cilindros de propano verticalmente v lvula hacia arriba Aseg...

Страница 20: ...nga del aire que necesita para la combusti n Consulte la secci n de especificaciones del manual del calentador la placa del calentador o p ngase en contacto con el fabricante para conocer los requerim...

Страница 21: ...re la salida de gas en el cilindro o los cilindros de suministro de gas LP cuando no est utilizando el calentador 4 Cuando deba guardar el calentador en un lugar cerrado deber desconectar la conexi n...

Страница 22: ...al hasta encontrar el tiempo de funcionamiento deseado a la izquierda del gr fico 3 Lea el tama o de cilindro requerido Todos los calentadores deben tener cilindros llenos buena circulaci n de aire ci...

Страница 23: ...ula de flujo en exceso POL 1 16 26122 Conexi n del acople macho 1 3 8 MPT x 3 8S AE FLR 17 26101 V lvula del solenoide Goyen 1 18 28775 Uni n de cierre del acople 1 19 28777 V lvula de ajuste de la ta...

Страница 24: ...tamento de mantenimiento Mr Heater Inc 45125 W 1125 TH ST CLEVELAND OHIO 44135 Incluya su nombre direcci n y n mero de tel fono as como los detalles relativos al reclamo Adem s inf rmenos la fecha de...

Отзывы: