6
3. ANALYZER OPTIONS
Standard Equipment
A. Internal storage capacity of 500 buffers
B. Integrated 2” thermal printer
C. Serial communications via USB or RS-232 connection
D. Custom-fuel programming
Optional Equipment
E. Additional pump and O
2
sensor for dual-range measurement and purging
capability
F. Bluetooth wireless communications
The ENERAC Model 700 is the most advanced portable emissions analyzer. It
uses the latest proprietary (SEM
TM
) electrochemical sensors, and non-dispersive
infrared (NDIR) technology to measure emissions.
The ENERAC Model 700 is an extremely versatile emissions measurement system
that meets practically all emissions measurement requirements:
• Measuring stack temperature and oxygen concentration.
• Measuring the ambient temperature inside the analyzer where the sensors are
located, as specified by the EPA method CTM-030
• Measuring the emissions of carbon monoxide, oxides of nitrogen, and sulfur
dioxide from stationary and mobile combustion sources by means of high-
quality (SEM) electrochemical sensors.
• Measuring the oxide of nitrogen emissions in accordance with the EPA
Provisional Reference Method ( CTM-030) for portable NOX analyzers.
• Measuring, carbon monoxide, carbon dioxide, and gaseous hydrocarbons as
propane using NDIR technology. The Model 700 meets EPA’s Reference
Method 25B Appendix A 40CFR60 “Determination of Total Gaseous Organic
Concentration Using a Non-dispersive Infrared Analyzer”.
• Computing the emission rates in parts-per-million (PPM), pounds-per-million-
BTU, or grams-per-brake-horsepower-hour; mass-emissions
Содержание 700
Страница 2: ...2 ENERAC 700 MANUAL EDITION 4 M700 FIRMWARE 3 0 M 700 HARDWARE H ...
Страница 4: ...4 APPENDIXC EPA TEST METHODS 70 ...
Страница 14: ...14 ...
Страница 18: ...18 ...
Страница 20: ...20 ...
Страница 49: ...49 ...
Страница 63: ...63 ...
Страница 67: ...67 ...