33
CHAPTER 6
ANALYZER SETUP
The SETUP MENU allows the operator to change system parameters.
MAR 1 ‘12 12:45:00
Fuel: Natural Gas
Temperature Units: F
Measure Units: PPM
OxygenReference:TRUE
Pumps:SAMPLEDuty:90%
Dilute CO: 10000 PPM
CO-IR Thresh:2000PPM
Cooler Duty: 50%
Thermal Eff:0.30
Baudrate: 9.6 kbps
Velocity Units: FPS
Stack Size: 5000sqin
Version: 3.0
Every parameter listed on the SETUP MENU screen can be changed as follows.
1. Use the
UP / DOWN
keys to move the cursor to the parameter you wish to
change.
2. Press
ENTER
to select the parameter. The value will be highlighted. This
indicates that you are in edit mode.
3. Use the
UP / DOWN
keys until the desired value of the selected parameter
appears on the display.
4. Press the
ENTER
key to confirm the selection. If you want to
cancel
any
changes made, simply press any MENU key.
A more detailed explanation of each parameter follows.
1) DATE & TIME: The analyzer’s internal clock is displayed in the format
month-day-year, hour-minute-second. Hours are always displayed using a 24-
hour clock.
2) FUEL: The fuel selection affects the following parameters: combustion
efficiency, carbon dioxide calculation, and display of toxic gases in units other
than PPM. The analyzer has the following fifteen fuels stored in its memory: