20
21
4. Pinout
Connector assignment for DC voltage controlled lenses
Description
1 Damping (-)
2 Damping (+)
3 Control (+)
4 Control (-)
1
3
4
2
Lens connection AE status of menu should be selected to manual mode and shutter speed is fixed at
normal status.
A/I switch in
dc
position
Signal level To be optimized with LEVEL potentiometer
Remark
Use only DC voltage controlled lenses with internationally standardized plug pinout.
1
3
4
2
Connector assignment for Videosignal controlled lenses
Description Colour
1 Supply voltage red
2 N.C. –
3 Video white
4 Ground black
Lens connection AE status of menu should be selected to manual mode and shutter speed is fixed at
normal status.
A/I switch in
video
position
Signal level Optimise via the „LEVEL” regulator on the AI lens.
Note
Only switch on the power supply when all the other connections have been carried out.
The use of power supply units with stabilised output voltage (12VDC ±10%) is
recommended.
Power Supply at the VKC-1330IR12-24
G
12VDC
G
24VAC