![Endress+Hauser soliphant II FTM 30 DR Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/endress-hauser/soliphant-ii-ftm-30-dr/soliphant-ii-ftm-30-dr_operating-instructions-manual_2408466034.webp)
9.3 Accessories
Mounting accessories for separate housing T3
Mounting accessories: 1 bracket, 1 clamp, 2 screws, 2 nuts are also supplied.
This enables the separate housing to be easily mounted on a wall or 2" pipe.
Protective Hood
Protects the field-mounted Soliphant
from condensation in the sensor housing
F6 which can occur due to extreme
temperature variations.
Sliding Sleeve
When mounting the FTM 31 DR sensor
in the silo from above, the sliding sleeve
allows the switch point to be infinitely
adjusted.
Rope Shortening Set
This is for use with the FTM 32 DR sensor
It consists of a number of accessories,
which enable the rope to be shortened
and to make a permanent water-tight
connection with the sensor.
Instructions for mounting are included.
~2.4
ø
0.24
~ 3.4
2.6
0.12
ø 0.24
2.76
3.19
1.1
BA1
75Y
28
Fig. 28
Mouting accessories
for separate housing T3
Left:
Bracket for wall mounting
Right:
Clamp for mounting on
a 2" pipe
Dimensions in inches
1 in = 25.4 mm
4.33
6.38
4.02
B
A
175
Y29
Fig. 29
Protective hood
For sensor housing F6
Material: polyamide
Weight: 0.29 lbs (0.13 kg)
Order No.: 942262-0000
0.98
max.
4.6
1.73
DIN ISO 228
G2
BA17
5
Y3
0
Fig. 30
Sliding sleeve
Maximum permissible operating
pressure:
150 psi (10 bar);
Max. operating temperature:
180 °F (80 °C);
Packing for threaded
gland:
PTFE glass fabric;
Weight: 5.7 lbs (2.6 kg)
Material: steel
Order No.: 916538-0000
Material:
stainless
steel AISI 316 Ti
Order No.: 916538-0001
BA
175
Y31
Fig. 31
Rope shortening set
Order No.: 935622-0001
9 Technical Data
FTM 30 R, FTM 31 DR, FTM 32 DR
34
Hauser