Mounting
Prosonic M FMU44 HART
14
Hauser
F
E
BD
SD
A0038238
11
Parameter for the correct operation of the device
BD Blocking distance
SD Safety distance
E
Empty calibration
F
Measuring span
Mounting nozzle
L
D
A0038371
12
Definition of nozzle length L and nozzle diameter D
D
Nozzle diameter
L
Nozzle length
Conditions
• Smooth interior surfaces in pipe nozzle
Remove any edges or welded joints and burr on the inside of the tank side nozzle end
• To minimize disturbing factors: nozzle with an angled socket edge (ideally 45 °)
• Observe maximum nozzle length
Maximum nozzle length
400 mm (15.7 in) for the following nozzle diameters:
• DN150/6"
• DN200/8"
• DN250/10"
• DN300/12"
5.2.3
Safety distance
The device generates a warning or alarm if the level reaches the safety distance (SD). The
SD size can be set as required by the user in the
Safety distance (015)
function.