Proservo NMS81
22
Hauser
Data for passive usage (input or output)
D
E
F
C
B
A
1
1
1
1
3
2
2
4
1
HR
CDI
WP
on
SIM
2
2
3
3
4
4
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
i
G
1
3
2
POWER
-
+
!
E
G
F
1
1
1
3
2
2
4
HR
CDI
WP
on
SIM
i
D
C
B
A
1
1
2
2
3
3
4
4
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
G
1
3
2
POWER
A0033030
9
Passive input or output: Use terminals 1 and 2
Minimum terminal voltage
10.4 V
Maximum terminal voltage
29 V
Data for active usage (input or output)
D
E
F
C
B
A
1
1
1
1
3
2
2
4
1
HR
CDI
WP
on
SIM
2
2
3
3
4
4
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
i
G
1
3
2
POWER
-
+
E
G
F
1
1
1
3
2
2
4
HR
CDI
WP
on
SIM
i
D
C
B
A
1
1
2
2
3
3
4
4
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
G
1
3
2
POWER
A0033031
10
Active input or output: Use terminals 2 and 3
Transmitter power supply voltage
(Ex d/XP)
18.5 V - 360 Ω ⋅ I
load
Transmitter power supply voltage
(Ex i/IS)
20.0 V - 360 Ω ⋅ I
load
Output load
max. 500 Ω including signal line