Proservo NMS81
18
Hauser
I/O modules
Overview
E
G
F
1
1
1
1
3
2
2
2
4
HR
CDI
WP
on
SIM
POWER
i
D
C
B
A
1
1
2
2
3
3
4
4
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
D
E
F
C
B
A
1
1
1
1
3
2
2
4
1
HR
CDI
WP
on
SIM
2
2
3
3
4
4
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
i
G
1
3
2
POWER
A0027363
8
Position of the I/O modules in the terminal compartment
The terminal compartment contains up to four I/O modules, depending on the order code.
• Modules with four terminals can be in any of these slots.
• Modules with eight terminals can be in slot B or C.
The exact assignment of the modules to the slots is dependent on the device version. For a
detailed description refer to the Operating Instructions of the device in question.
The following restrictions apply when selecting the modules:
• The device may contain a maximum of four I/O modules.
• A maximum of two I/O modules with 8 terminals is possible.
Ordering feature 040: "Primary Output"
NMx8x -
XX xx xx
xxxx
...
040
Option Number of I/O modules
Type of I/O module
Number of terminals
Technical data
A1
1
Modbus RS485
4
B1
1
V1
4
E1
1
4-20mA HART Ex d/XP
8
H1
1
4-20mA HART Ex i/IS
8
Ordering feature 050: "Secondary IO Analogue"
NMx8x -
xx XX xx
xxxx
...
050
Option Number of I/O
modules
Type of I/O module
Number of terminals Technical data
A1
1
1 x "Ex d/XP 4-20mA HART + RTD input" 1 x 8
A2
2
2 x "Ex d/XP 4-20mA HART + RTD input" 2 x 8
B1
1
1 x "Ex i/IS 4-20mA HART+ RTD input"
1 x 8
B2
2
2 x "Ex i/IS 4-20mA HART+ RTD input"
2 x 8
C2
2
1 x "Ex i/IS 4-20mA HART + RTD input"
1 x "Ex d/XP 4-20mA HART + RTD input"
2 x 8
X0
0
none
0
-