Proline Prosonic Flow 92F
6
Hauser
Outputs/inputs (Item No. 18 in type code
)
Note!
A detailed explanation of these values with regard to the inputs and outputs available, as well as a description
of the associated terminal assignments and connection data is provided on Page 8 onwards.
Compact version
temperature table
Medium temperature range Tmed [°C] depending on the device version (see Page 5) and the ambient
temperature range T
a
:
Remote version
temperature table
Sensor
Medium temperature range Tmed [°C] depending on the device version (see Page 5) and the ambient
temperature range T
a
:
Transmitter
Ambient temperature range Ta [°C] depending on the device version (see Page 5):
Design of the measuring
system
Compact/remote version design
*
Approval
A, W
Cl. I, Groups ABCD
Cl. II, Groups EFG
Cl. III
Cl. I, Zone 1, AEx/Ex d [ia] IIC T6 - T1
H, K
Cl. I, Groups ABCD
Cl. II, Groups EFG
Cl. III
Cl. I, Zone 1, AEx/Ex d [ia] IIC T4 - T1
T
a
T
med
[°F]
T6
(185 °F)
T5
(212 °F)
T4
(275 °F)
T3
(392 °F)
T2
(572 °F)
T1
(842 °F)
Prosonic 92F**-*****P*****A/W
–40 to +104
–40 to 176
–40 to 203
–40 to 266
–40 to 383
–40 to 392
–40 to 392
–40 to +131
–
–40 to 203
–40 to 266
–40 to 383
–40 to 392
–40 to 392
–40 to +140
–
–
–40 to 266
–40 to 383
–40 to 392
–40 to 392
Prosonic 92F**-*****P*****H/K
–40 to +140
–
–
–40 to 266
–40 to 383
–40 to 392
–40 to 392
T
a
T
med
[°F]
T6
(185 °F)
T5
(212 °F)
T4
(275 °F)
T3
(392 °F)
T2
(572 °F)
T1
(842 °F)
Prosonic 92F**-*****P*****A/W
–40 to +140
–40 to 176
–40 to 203
–40 to 266
–40 to 383
–40 to 392
–40 to 392
–40 to +185
–
–40 to 203
–40 to 266
–40 to 383
–40 to 392
–40 to 392
Prosonic 92F**-*****P*****H/K
–40 to +185
–
–
–40 to 266
–40 to 383
–40 to 392
–40 to 392
T
med
T6
(185 °F)
T5
(212 °F)
T4
(275 °F)
T3
(392 °F)
T2
(572 °F)
T1
(842 °F)
Prosonic 92F**-*****P*****A/W
–40 to 104
–40 to 131
–40 to 176
–40 to 176
–40 to 176
–40 to 176
Prosonic 92F**-*****P*****H/K
–
–
–40 to 176
–40 to 176
–40 to 176
–40 to 176
Fig. 2:
A0004031
A
Transmitter housing (compact version)
a
Screw terminal for connecting to potential matching system
B
Connection housing transmitter (remote version)
b
Screw terminal for connecting to potential matching system
C
Connection housing sensor (remote version)
c
Screw terminal for connecting to potential matching system
d
Remote version connecting cable
– Connecting cable cable specifications
– Cable entries
– Terminal assignment and connection data
IN
EX
PLO
SIV
EA
TM
OS
PH
ER
E
KE
EP
H
TIG
HT
W
EN
CIR
CU
IT
AL
IV
E
WARNING
N
IC
H
T U
NTE
R SPANNUNG
ÖFF
N
EN
AVERTISSEMENT
N
E
S
PA
S O
UVR
IR
OUS
TEN
SIO
N
WARNUNG
A
B
C
c
a
d
b