1
Proline Prosonic Flow 92F
12
Hauser
Outputs/inputs (Item No. 18 in type code
)
!
Note!
A detailed explanation of these values with regard to the inputs and outputs available, as well as a description
of the associated terminal assignments and connection data is provided on Page 14 onwards.
Compact version
temperature table
Medium temperature range Tmed [°C] depending on the device version (see Page 11) and the ambient
temperature range T
a
:
Remote version
temperature table
Sensor
Medium temperature range Tmed [°C] depending on the device version (see Page 11) and the ambient
temperature range T
a
:
Transmitter
Ambient temperature range Ta [°C] depending on the device version (see Page 11):
Design of the measuring
system
Compact/remote version design
*
Approval
A, W
Cl. I, Groups ABCD
Cl. II, Groups EFG
Cl. III
Cl. I, Zone 1, AEx/Ex d [ia] IIC T6 - T1
H, K
Cl. I, Groups ABCD
Cl. II, Groups EFG
Cl. III
Cl. I, Zone 1, AEx/Ex d [ia] IIC T4 - T1
T
a
T
med
[°C]
T6
(85 °C)
T5
(95 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Prosonic 92F**-*****P*****A/W
–40 to +40
–40 to 80
–40 to 95
–40 to 130
–40 to 195
–40 to 200
–40 to 200
–40 to +55
–
–40 to 95
–40 to 130
–40 to 195
–40 to 200
–40 to 200
–40 to +60
–
–
–40 to 130
–40 to 195
–40 to 200
–40 to 200
Prosonic 92F**-*****P*****H/K
–40 to +60
–
–
–40 to 130
–40 to 195
–40 to 200
–40 to 200
T
a
T
med
[°C]
T6
(85 °C)
T5
(95 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Prosonic 92F**-*****P*****A/W
–40 to +60
–40 to 80
–40 to 95
–40 to 130
–40 to 195
–40 to 200
–40 to 200
–40 to +80
–
–40 to 95
–40 to 130
–40 to 195
–40 to 200
–40 to 200
Prosonic 92F**-*****P*****H/K
–40 to +80
–
–
–40 to 130
–40 to 195
–40 to 200
–40 to 200
T
med
T6
(85 °C)
T5
(95 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Prosonic 92F**-*****P*****A/W
40
–40 to 55
–40 to 80
–40 to 80
–40 to 80
–40 to 80
Prosonic 92F**-*****P*****H/K
–
–
–40 to 80
–40 to 80
–40 to 80
–40 to 80
Fig. 2
A0004031
A
Transmitter housing (compact version)
a
Screw terminal for connecting to potential matching system
B
Connection housing transmitter (remote version)
b
Screw terminal for connecting to potential matching system
C
Connection housing sensor (remote version)
c
Screw terminal for connecting to potential matching system
d
Remote version connecting cable
– Connecting cable cable specifications
– Cable entries
– Terminal assignment and connection data
IN
EX
PLO
SIV
EA
TM
OS
PH
ER
E
KE
EP
H
TIG
HT
W
EN
CIR
CU
IT
AL
IV
E