PROFIBUS DP connection version
For use in the non-hazardous area and Zone 2/Div. 2.
Order code for "Output", option
L
Depending on the housing version, the transmitters can be ordered with terminals or device plugs.
Order code for
"Housing"
Connection methods available
Possible options for order code
"Electrical connection"
Output
Power
supply
Options
A
,
B
Terminals
Terminals
• Option
A
: coupling M20x1
• Option
B
: thread M20x1
• Option
C
: thread G ½"
• Option
D
: thread NPT ½"
Options
A
,
B
Device plug
Terminals
• Option
L
: plug M12x1 + thread NPT ½"
• Option
N
: plug M12x1 + coupling M20
• Option
P
: plug M12x1 + thread G ½"
• Option
U
: plug M12x1 + thread M20
Options
A
,
B
,
C
Device plug
Device plug
Option
Q
: 2 x plug M12x1
Order code for "Housing":
• Option
A
: compact, coated aluminum
• Option
A
: compact, hygienic, stainless
• Option
C
: ultra compact, hygienic, stainless, M12 device plug
L
L
26
27
B
A
1
2
+
_
1
2
A0022716
3
PROFIBUS DP terminal assignment
1
Power supply: DC 24 V
2
PROFIBUS DP
Order code for
"Output"
Terminal number
Power supply
Output
2 (L-)
1 (L+)
26 (RxD/TxD-P)
27 (RxD/TxD-
N)
Option
L
DC 24 V
B
A
Order code for "Output":
Option
L
: PROFIBUS DP, for use in non-hazardous areas and Zone 2/div. 2