O → T configuration:
0x66
64
T → O configuration:
0x65
88
Input only Multicast
Instance
Size [byte]
Instance configuration:
0x68
398
O → T configuration:
0xC7
-
T → O configuration:
0x65
88
Input only Multicast
Instance
Size [byte]
Instance configuration:
0x69
-
O → T configuration:
0xC7
-
T → O configuration:
0x65
88
Configurable Input Assembly
• Current device diagnostics
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3
The range of options increases if the measuring device has one or
more application packages.
Fix Output
Output Assembly
• Activation of reset totalizers 1-3
• Activation of pressure compensation
• Activation of reference density compensation
• Activation of temperature compensation
• Reset totalizers 1-3
• External pressure value
• Pressure unit
• External reference density
• Reference density unit
• External temperature
• Temperature unit
Configuration
Configuration Assembly
Only the most common configurations are listed below.
• Software write protection
• Mass flow unit
• Mass unit
• Volume flow unit
• Volume unit
• Corrected volume flow unit
• Corrected volume unit
• Density unit
• Reference density unit
• Temperature unit
• Pressure unit
• Length
• Totalizer 1-3:
– Assignment
– Unit
– Measuring mode
– Failure mode
• Alarm delay