Promag 50/53 W
Hauser
17
Process conditions
Medium temperature range
The permissible medium temperature depends on the measuring tube liner:
•
Polyurethane, -5° to +125°F (-20° to +50°C) for 1” to 78” sensors
•
Hard rubber, 32° to +180°F (0° to +80°C) for 3” to 78” sensors
Conductivity
Minimum conductivity:
≥
5
µ
S/cm
→
for fluids generally
≥
20
µ
S/cm
→
for demineralized water
Note that in the case of the remote version, the minimum conductivity is also influ-
enced by the length of the connecting cable. Refer to “Length of connecting cable”.
ANSI B 16.5:
Class 150, 1” to 24”
Class 300, 1” to 6”
AWWA:
Class D, 28” to 78”
Medium pressure range
(nominal pressure)
Pressure tightness (liner)
Size
Measuring Resistance to partial vacuum of measuring tube lining
tube limit values for abs. pressure (psia) at various
lining
fluid temperatures
75°F 160°F 175°F 212°F 265°F 300°F 355°F
1” to 40” Polyurethane 0 0 - - - - -
3” to 78” Hard rubber 0 0 0 -
- - -