System integration
The measuring device has an IO-Link communication interface. The IO-Link interface
allows direct access to process and diagnostics data and enables the user to configure the
measuring device on the fly.
Properties:
• IO-Link Specification: Version 1.1
• IO-Link Smart Sensor Profile 2nd Edition
• SIO mode: yes
• Speed: COM2 (38.4 kBaud)
• Minimum cycle time: 10 ms
• Process data width: 120 bit
• IO-Link data storage: yes
• Block configuration: no
• Device operational: The measuring device is operational 4 seconds after the supply
voltage is applied
More information on IO-Link is available at
www.io-link.com
Overview of the entire IO-Link ISDU parameter list → 52
8.1
Overview of device description files
Current version data for the device
Firmware version
01.01.zz
Information on the firmware version can be found:
• On the title page of the Operating instructions
• On the device label
• In the
Firmware version
parameter in the System menu
Release date of firmware
version
05.2019
---
Profile version
• 1.1
• Smart Sensor
Profile
---
8.2
Device master file
In order to integrate field devices into a digital communication system, the IO-Link system
needs a description of the device parameters, such as output data, input data, data format,
data volume and supported transfer rate.
These data are available in the device master file (IODD
), provided to the IO-Link master
when the communication system is commissioned.
The IODD can be downloaded as follows:
• Hauser:
www.endress.com
• IODDfinder:
http://ioddfinder.io-link.com
1)
IO Device Description