5.1.6
Measurement in plastic vessels
3
1
2
A0029540
8
Measurement in a plastic vessel with a metallic, interfering installation outside of the vessel
1
Pipe, tubing
2
Ladder
3
Grate, railing
If the outer wall of the vessel is made of a non-conductive material (e.g. GFR), microwaves
can also be reflected by interfering installations outside of the vessel.
Please ensure there are no interfering installations made of a conductive material in the
signal beam (see the beam angle section for information on calculating the beamwidth
diameter).
Please contact the manufacturer for further information.
5.1.7
Weather protection cover
For outdoor use, a weather protection cover is recommended.
The weather protection cover is available as an accessory.
A0031277
9
Weather protection cover with 40 mm (1.5 in) antenna
The sensor is not completely covered by the protection cover.