Liquisys M CUM223/253
Technical data
Hauser
99
11.3
Power supply
Supply voltage
Depending on ordered version:
100/115/230 V AC +10/-15 %, 48 to 62 Hz
24 V AC/DC +20/-15 %
Fieldbus connection
Power consumption
max. 7.5 VA
Mains protection
Fine-wire fuse, medium-slow blow 250 V/3.15 A
HART
Supply voltage
n/a, active current outputs
Integrated reverse voltage protection
n/a, active current outputs
PROFIBUS PA
Supply voltage
9 V to 32 V, max. 35 V
Polarity sensitive
no
FISCO/FNICO compliant acc. to IEC 60079-27 no
PROFIBUS DP
Supply voltage
9 V to 32 V, max. 35 V
Polarity sensitive
n/a
FISCO/FNICO compliant acc. to IEC 60079-27 no